{"title":"Active noise control of one-dimensional duct via sampled-data H/sub /spl infin// control","authors":"Y. Kobayashi, H. Fujioka","doi":"10.1109/CDC.2003.1271758","DOIUrl":null,"url":null,"abstract":"This paper deals with a synthesis problem for active noise control systems for one-dimensional duct. Since it is important to reduce the cost of the active noise control systems for practical use, the sampled-data H/sub /spl infin// control synthesis is applied to design a digital controller with long sampling period. As a conventional synthesis method, continuous-time H/sub /spl infin// control based synthesis is also applied, where the Tustin transformation is used to discretize continuous-time H/sub /spl infin// controllers. The experimental results show that the conventional method work well for short sampling period, however, when the sampling period is not short enough, the system loose stability. In contrast, the sampled-data H/sub /spl infin// control synthesis does not cause such problems, and longer sampling period is achieved without performance degradation compared to the conventional method.","PeriodicalId":371853,"journal":{"name":"42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475)","volume":"186 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CDC.2003.1271758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This paper deals with a synthesis problem for active noise control systems for one-dimensional duct. Since it is important to reduce the cost of the active noise control systems for practical use, the sampled-data H/sub /spl infin// control synthesis is applied to design a digital controller with long sampling period. As a conventional synthesis method, continuous-time H/sub /spl infin// control based synthesis is also applied, where the Tustin transformation is used to discretize continuous-time H/sub /spl infin// controllers. The experimental results show that the conventional method work well for short sampling period, however, when the sampling period is not short enough, the system loose stability. In contrast, the sampled-data H/sub /spl infin// control synthesis does not cause such problems, and longer sampling period is achieved without performance degradation compared to the conventional method.