Maximum power control of grid-connected DFIG-based wind systems

A. Sylla, M. Doumbia
{"title":"Maximum power control of grid-connected DFIG-based wind systems","authors":"A. Sylla, M. Doumbia","doi":"10.1109/EPEC.2012.6474963","DOIUrl":null,"url":null,"abstract":"This paper presents maximum power control of doubly-fed induction generator (DFIG) based grid-connected wind energy system. The control system used a combination of MPPT method with pitch control to extract maximum power from the wind turbine. PWM hysteresis controller is used to control the back to back converter which output is connected to the utility grid through a multivariable filter. The overall wind system is theoretically analyzed and modeled in Matlab/Simulink/ SimPowerSystems environment. The grid-connected wind system's performances are evaluated.","PeriodicalId":118103,"journal":{"name":"2012 IEEE Electrical Power and Energy Conference","volume":"2010 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Electrical Power and Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2012.6474963","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

This paper presents maximum power control of doubly-fed induction generator (DFIG) based grid-connected wind energy system. The control system used a combination of MPPT method with pitch control to extract maximum power from the wind turbine. PWM hysteresis controller is used to control the back to back converter which output is connected to the utility grid through a multivariable filter. The overall wind system is theoretically analyzed and modeled in Matlab/Simulink/ SimPowerSystems environment. The grid-connected wind system's performances are evaluated.
基于dfig的并网风电系统最大功率控制
研究了双馈感应发电机并网风电系统的最大功率控制问题。该控制系统采用MPPT法和俯仰控制相结合的方法,从风力机中提取最大功率。PWM迟滞控制器用于控制输出通过多变量滤波器连接到电网的背对背变换器。在Matlab/Simulink/ SimPowerSystems环境下对整个风系统进行了理论分析和建模。对并网风系统的性能进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信