A new extremely small sensor for measuring a blood flow and a contact pressure simultaneously

R. Inoue, Hirofumi Nogami, E. Higurashi, R. Sawada
{"title":"A new extremely small sensor for measuring a blood flow and a contact pressure simultaneously","authors":"R. Inoue, Hirofumi Nogami, E. Higurashi, R. Sawada","doi":"10.1109/OMN.2017.8051497","DOIUrl":null,"url":null,"abstract":"A number of laser Doppler blood flow sensors have been developed over the past few decades. However, they remain uncommon in practice. This is because the contact pressure between the skin and the sensor is not measured simultaneously with blood flow, despite the fact that blood flow is greatly affected by contact pressure. Thus, reliable and highly reproducible measurement of blood flow could not be realized. Therefore, we have developed a micro electro mechanical systems (MEMS) blood flow sensor which has a built-in pressure sensor, for reliable and highly reproducible measurement.","PeriodicalId":411243,"journal":{"name":"2017 International Conference on Optical MEMS and Nanophotonics (OMN)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Optical MEMS and Nanophotonics (OMN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMN.2017.8051497","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A number of laser Doppler blood flow sensors have been developed over the past few decades. However, they remain uncommon in practice. This is because the contact pressure between the skin and the sensor is not measured simultaneously with blood flow, despite the fact that blood flow is greatly affected by contact pressure. Thus, reliable and highly reproducible measurement of blood flow could not be realized. Therefore, we have developed a micro electro mechanical systems (MEMS) blood flow sensor which has a built-in pressure sensor, for reliable and highly reproducible measurement.
一种新型的非常小的传感器,可以同时测量血流量和接触压力
在过去的几十年里,许多激光多普勒血流传感器已经被开发出来。然而,它们在实践中仍然不常见。这是因为皮肤与传感器之间的接触压力并没有与血液流量同时测量,尽管血液流量受到接触压力的很大影响。因此,无法实现可靠且高重复性的血流量测量。因此,我们开发了一种微机电系统(MEMS)血流传感器,该传感器具有内置压力传感器,用于可靠和高度可重复性的测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信