Factors affecting the Gates' measurement of glomerular filtration rate.

M Awdeh, K Kouris, I M Hassan, H M Abdel-Dayem
{"title":"Factors affecting the Gates' measurement of glomerular filtration rate.","authors":"M Awdeh,&nbsp;K Kouris,&nbsp;I M Hassan,&nbsp;H M Abdel-Dayem","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The following technical factors affect the Gates' measurement of glomerular filtration rate (GFR): 1) net injected activity, 2) kidney depth, 3) corrected kidney counts. In the syringe measurement prior to injection, self-attenuation causes 16% data loss for a volume of 0.5 ml if the syringe is positioned perpendicular to the collimator face. A +/- 1 cm error in true kidney depth may cause a 16% difference in GFR in an adult. The choice of the background region of interest (ROI), for background subtraction significantly affects the calculation. To minimize errors in the Gates' estimate of GFR we recommend 1) that syringe counting be done with the syringe parallel to the collimator face; 2) that the i.v. set be included in the postsyringe measurement; in cases of extravasation, the injection site should also be counted; 3) that kidney depth, especially for ectopic and transplanted kidneys be estimated by ultrasound or using lateral views; and 4) that a background ROI for each kidney be used.</p>","PeriodicalId":76992,"journal":{"name":"American journal of physiologic imaging","volume":"5 1","pages":"36-41"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of physiologic imaging","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The following technical factors affect the Gates' measurement of glomerular filtration rate (GFR): 1) net injected activity, 2) kidney depth, 3) corrected kidney counts. In the syringe measurement prior to injection, self-attenuation causes 16% data loss for a volume of 0.5 ml if the syringe is positioned perpendicular to the collimator face. A +/- 1 cm error in true kidney depth may cause a 16% difference in GFR in an adult. The choice of the background region of interest (ROI), for background subtraction significantly affects the calculation. To minimize errors in the Gates' estimate of GFR we recommend 1) that syringe counting be done with the syringe parallel to the collimator face; 2) that the i.v. set be included in the postsyringe measurement; in cases of extravasation, the injection site should also be counted; 3) that kidney depth, especially for ectopic and transplanted kidneys be estimated by ultrasound or using lateral views; and 4) that a background ROI for each kidney be used.

影响盖茨测定肾小球滤过率的因素。
以下技术因素影响盖茨测量肾小球滤过率(GFR): 1)净注射活性,2)肾脏深度,3)校正后的肾脏计数。在注射前的注射器测量中,如果注射器垂直于准直器面,则自衰减会导致体积为0.5 ml的数据丢失16%。真实肾深+/- 1厘米的误差可能导致成人GFR的16%差异。背景减法中感兴趣的背景区域(ROI)的选择对计算结果有很大影响。为了最小化盖茨估计GFR的误差,我们建议1)注射器计数与准直器面平行;2)将静脉注射装置纳入注射后测量;如果发生外渗,还应计数注射部位;3)肾脏深度,特别是异位肾和移植肾,应通过超声或侧位图估计;4)使用每个肾脏的背景ROI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信