{"title":"Design, installation, and field experience with a real-time portable transformer monitoring system","authors":"F. Hoppe, R. Thompson","doi":"10.1109/TDC.1996.545913","DOIUrl":null,"url":null,"abstract":"A portable transformer monitoring system has been developed and installed to monitor and store critical operating parameters of power transformers. The system's hardware, firmware, and software have been designed using an \"open\" architecture to provide maximum flexibility for parameter measurement and data presentation. A two-bank system can be placed in service in under three hours without requiring equipment outages and is readily expandable to include thermal modeling, alarm functions, pump and fan control, diagnostics and real-time ratings. The system can be interfaced to existing SCADA or EMS.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.1996.545913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A portable transformer monitoring system has been developed and installed to monitor and store critical operating parameters of power transformers. The system's hardware, firmware, and software have been designed using an "open" architecture to provide maximum flexibility for parameter measurement and data presentation. A two-bank system can be placed in service in under three hours without requiring equipment outages and is readily expandable to include thermal modeling, alarm functions, pump and fan control, diagnostics and real-time ratings. The system can be interfaced to existing SCADA or EMS.
具有便携式实时变压器监测系统的设计、安装和现场经验
为了监测和存储电力变压器的关键运行参数,研制并安装了便携式变压器监测系统。该系统的硬件、固件和软件采用“开放式”架构设计,为参数测量和数据呈现提供最大的灵活性。双银行系统可以在三小时内投入使用,而不需要设备停机,并且很容易扩展,包括热建模,报警功能,泵和风扇控制,诊断和实时评级。该系统可与现有的SCADA或EMS接口。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书