{"title":"Reactive power control of doubly fed induction generator in wind farm under low grid voltage","authors":"Dawei Wang, Haitao Wang, Junchuan Jia, Yigong Zhang","doi":"10.1109/CRIS.2010.5617514","DOIUrl":null,"url":null,"abstract":"This paper calculates the reactive power limit of DFIG (doubly fed induction generator), and discusses the current reactive power control schemes of DFIG. Three methods, which use both the grid and rotor side converters for voltage regulation and reactive power support, are analyzed and compared. This paper presents a new coordinated control strategy, which central idea is to use the grid-side converter as the main reactive power controller and the rotor side converter as auxiliary. The new presented control scheme is modeled on MATLAB/SIMULINK, and the results show the effectiveness of the proposed control scheme. Providing reactive power to grid can assist the recovery of the grid voltage.","PeriodicalId":206094,"journal":{"name":"2010 5th International Conference on Critical Infrastructure (CRIS)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 5th International Conference on Critical Infrastructure (CRIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CRIS.2010.5617514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

This paper calculates the reactive power limit of DFIG (doubly fed induction generator), and discusses the current reactive power control schemes of DFIG. Three methods, which use both the grid and rotor side converters for voltage regulation and reactive power support, are analyzed and compared. This paper presents a new coordinated control strategy, which central idea is to use the grid-side converter as the main reactive power controller and the rotor side converter as auxiliary. The new presented control scheme is modeled on MATLAB/SIMULINK, and the results show the effectiveness of the proposed control scheme. Providing reactive power to grid can assist the recovery of the grid voltage.
低电网电压条件下风电场双馈感应发电机无功控制
本文计算了双馈感应发电机的无功功率极限,讨论了双馈感应发电机的现有无功控制方案。分析比较了电网侧变流器和转子侧变流器共同进行电压调节和无功支持的三种方法。本文提出了一种新的协调控制策略,其核心思想是以电网侧变流器为主,转子侧变流器为辅。在MATLAB/SIMULINK中对所提出的控制方案进行了建模,结果表明了所提控制方案的有效性。向电网提供无功功率有助于电网电压的恢复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信