Screening vdsm outliers using nominal and subthreshold supply voltage I/sub DDQ/

C. Schuermyer, B. Benware, Kevin Cota, R. Madge, W. R. Daasch, L. Ning
{"title":"Screening vdsm outliers using nominal and subthreshold supply voltage I/sub DDQ/","authors":"C. Schuermyer, B. Benware, Kevin Cota, R. Madge, W. R. Daasch, L. Ning","doi":"10.1109/TEST.2003.1270883","DOIUrl":null,"url":null,"abstract":"Very Deep Sub-Micron (VDSM) defects are resolved as Statistical Post-Processing™ (SPP) outliers of a new IDDQ screen. The screen applies an IDDQ pattern once to the Device Under Test (DUT) and takes two quiescent current measurements. The quiescent current measurements are taken at nominal and at subthreshold supply voltages. The scr een is demonstrated with 0.18µm and 0.13µm volume data. The screen's effectiveness is compared to stuck -at and other IDDQ screens.","PeriodicalId":236182,"journal":{"name":"International Test Conference, 2003. Proceedings. ITC 2003.","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Test Conference, 2003. Proceedings. ITC 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TEST.2003.1270883","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Very Deep Sub-Micron (VDSM) defects are resolved as Statistical Post-Processing™ (SPP) outliers of a new IDDQ screen. The screen applies an IDDQ pattern once to the Device Under Test (DUT) and takes two quiescent current measurements. The quiescent current measurements are taken at nominal and at subthreshold supply voltages. The scr een is demonstrated with 0.18µm and 0.13µm volume data. The screen's effectiveness is compared to stuck -at and other IDDQ screens.
使用标称和亚阈值供电电压I/sub DDQ/筛选vdsm异常值
极深亚微米(VDSM)缺陷被解决为新的IDDQ屏幕的统计后处理™(SPP)异常值。屏幕对被测设备(DUT)应用一次IDDQ模式,并进行两次静态电流测量。静态电流测量在标称电压和亚阈值电压下进行。该屏幕显示了0.18µm和0.13µm的体积数据。该屏幕的有效性与卡在和其他IDDQ屏幕进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信