Telescopic versus Bar attachments for three-implants assissed mandibular overdenture (Comparative study of retention)

Salah A. Hegazy, R. Emera, Ahmed M. Mahmoud
{"title":"Telescopic versus Bar attachments for three-implants assissed mandibular overdenture (Comparative study of retention)","authors":"Salah A. Hegazy, R. Emera, Ahmed M. Mahmoud","doi":"10.21608/mjd.2021.199976","DOIUrl":null,"url":null,"abstract":"It could be hypothesised that attachments, which provide more retention against dislodgement forces, will be associated with more favourable parameters of oral function.. This in vivo study is designed to provide data regarding retention force and chewing efficiency at insertion, after 3 and 6 months of function with the use of bar clip (group1)&telescopic attachments(group 2) in mandibular overdenture treatment. Six healthy male completely edentulous patients will be selected from the outpatient clinic of Prosthodontic Department, Faculty of dentistry, Mansoura University, Egypt. Each patient will receive three dental implants in the 2 in the canine region of the mandible bilateraaly and one in the midline and two suprastructure modalities (bar and telescopic attachments ). The retention force of the attachments at insertion , after 3 and six months was measured in a standardized way. The amount of retention that was related to the attachment were evaluated. The difference in retention force at insertion , after 3 and 6 months observed for bar-clip attachments. Decrease of bar-clip retention from at insertion to 3& 6 months at bar attachment (from 20.07 to 9.1 and 6.5 , respectively). Slight differences in retention force at insertion, after 3and 6 months were observed for telescopic attachments.(mean retention 8.5).chewing efficiency at insertion , 3 and 6 months was measured in s standardize way. The mean chewing efficiency illustrates statistically significant higher mean among bar attachment than telescopic attachment at insertion , after 3 and 6 months. Chewing efficiency illustrates increased mean by increasing number of cycles. Purpose:The aim of this within patient study was to evaluate the effect of linear distribution of implant supported mandibular over denture using bar and telescopic attachments on the retention and chewing efficiency. Methods:Six male patients ofSix healthy male patients ranged between 48-60 years old were included in the study. For each patientrecieveda conventional complete denture before implant surgery was performed in the midline and two canine areas. After healing period, the conventional denture was converted into implant supported overdentureattached to three implants and checked forretention at insertion and 3 and 6 months later by forcemeter and masticatory efficiency was evaluated at insertion 3 and 6 months later by two-colored chewing gum.Repeated Measures ANOVA test was used to compare more than 2 studied periods with post Hoc test Tukey test. Two & three Way ANOVA tests were used to assess the effect of combination of 2 or 3 independent factors on continuous parametric outcome (retention and chewing efficiency ). Results: Mean retention illustrates statistically significant higher value among Bar attachment than telescopic at insertion (20.07 and 8.5) , while there is statistically significant lower value among bar than telescopic attachment(6.5 and 8.83). Repeated Measures ANOVA illustrates statistically significant decrease of retention from at insertion to 3& 6 months at bar attachment (from 20.07 to 9.1 and 6.5 , respectively). Mean chewing efficiency illustrates statistically significant higher mean among bar attachment than telescopic attachment at insertion , after 3 and 6 months. Chewing efficiency illustrates increased mean by increasing number of cycles.","PeriodicalId":308616,"journal":{"name":"Mansoura Journal of Dentistry","volume":"21 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mansoura Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/mjd.2021.199976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

It could be hypothesised that attachments, which provide more retention against dislodgement forces, will be associated with more favourable parameters of oral function.. This in vivo study is designed to provide data regarding retention force and chewing efficiency at insertion, after 3 and 6 months of function with the use of bar clip (group1)&telescopic attachments(group 2) in mandibular overdenture treatment. Six healthy male completely edentulous patients will be selected from the outpatient clinic of Prosthodontic Department, Faculty of dentistry, Mansoura University, Egypt. Each patient will receive three dental implants in the 2 in the canine region of the mandible bilateraaly and one in the midline and two suprastructure modalities (bar and telescopic attachments ). The retention force of the attachments at insertion , after 3 and six months was measured in a standardized way. The amount of retention that was related to the attachment were evaluated. The difference in retention force at insertion , after 3 and 6 months observed for bar-clip attachments. Decrease of bar-clip retention from at insertion to 3& 6 months at bar attachment (from 20.07 to 9.1 and 6.5 , respectively). Slight differences in retention force at insertion, after 3and 6 months were observed for telescopic attachments.(mean retention 8.5).chewing efficiency at insertion , 3 and 6 months was measured in s standardize way. The mean chewing efficiency illustrates statistically significant higher mean among bar attachment than telescopic attachment at insertion , after 3 and 6 months. Chewing efficiency illustrates increased mean by increasing number of cycles. Purpose:The aim of this within patient study was to evaluate the effect of linear distribution of implant supported mandibular over denture using bar and telescopic attachments on the retention and chewing efficiency. Methods:Six male patients ofSix healthy male patients ranged between 48-60 years old were included in the study. For each patientrecieveda conventional complete denture before implant surgery was performed in the midline and two canine areas. After healing period, the conventional denture was converted into implant supported overdentureattached to three implants and checked forretention at insertion and 3 and 6 months later by forcemeter and masticatory efficiency was evaluated at insertion 3 and 6 months later by two-colored chewing gum.Repeated Measures ANOVA test was used to compare more than 2 studied periods with post Hoc test Tukey test. Two & three Way ANOVA tests were used to assess the effect of combination of 2 or 3 independent factors on continuous parametric outcome (retention and chewing efficiency ). Results: Mean retention illustrates statistically significant higher value among Bar attachment than telescopic at insertion (20.07 and 8.5) , while there is statistically significant lower value among bar than telescopic attachment(6.5 and 8.83). Repeated Measures ANOVA illustrates statistically significant decrease of retention from at insertion to 3& 6 months at bar attachment (from 20.07 to 9.1 and 6.5 , respectively). Mean chewing efficiency illustrates statistically significant higher mean among bar attachment than telescopic attachment at insertion , after 3 and 6 months. Chewing efficiency illustrates increased mean by increasing number of cycles.
套筒式与杆式附着体在三种植体辅助下颌覆盖义齿固位中的比较研究
可以假设,附着物,提供更多的保留对抗位移力,将与更有利的口腔功能参数相关联。这项体内研究旨在提供在使用棒夹(组1)和伸缩附着物(组2)治疗下颌覆盖义齿3个月和6个月后插入时固位力和咀嚼效率的数据。从埃及曼苏拉大学牙科学院修复科门诊选择6名健康男性全牙缺牙患者。每位患者将接受三颗牙种植体,分别在双侧下颌骨犬齿区和中线区,以及两种上结构形式(棒状和伸缩附件)。采用标准化方法测量附着体在插入时、3个月和6个月后的固位力。评估了与依恋相关的保留量。3个月和6个月后观察棒夹附着物插入时固位力的差异。棒夹保留率从插入时降至3和6个月(分别从20.07降至9.1和6.5)。3个月和6个月后观察到伸缩附着物插入时的固位力略有差异。(平均保留率8.5)。采用5种标准方法测定插入、3、6个月时咀嚼效率。3个月和6个月后,棒状附着体的平均咀嚼效率显著高于伸缩附着体。咀嚼效率随着循环次数的增加而增加。目的:本研究的目的是评估线性分布的种植支撑下颌义齿使用杆和伸缩附着体对固位和咀嚼效率的影响。方法:选取6例健康男性患者,年龄48 ~ 60岁。每位患者在种植手术前在中线和两个犬齿区域进行了常规全口义齿。修复期结束后,将常规义齿转化为种植支撑覆盖义齿,附着三颗种植体,在植牙3个月和6个月后用力计检查固位情况,在植牙3个月和6个月后用双色口香糖评估咀嚼效率。2个以上研究期的比较采用重复测量方差分析(Repeated Measures ANOVA)和事后检验(post Hoc)。采用二路和三路方差分析(Two & three Way ANOVA)检验来评估2或3个独立因素组合对连续参数结果(固位和咀嚼效率)的影响。结果:平均固位在插入时,杆式固定比伸缩式固定高(20.07和8.5),而杆式固定比伸缩式固定低(6.5和8.83)。重复测量方差分析(Repeated Measures ANOVA)显示,从插入时到棒体附着3个月和6个月,保留率显著降低(分别从20.07降至9.1和6.5)。3个月和6个月后,棒状附着体的平均咀嚼效率高于伸缩附着体。咀嚼效率随着循环次数的增加而增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信