Significance of working point determining line current harmonics in controlled AC/DC converter

M. Grotzbach, M. Bauta
{"title":"Significance of working point determining line current harmonics in controlled AC/DC converter","authors":"M. Grotzbach, M. Bauta","doi":"10.1109/ICPS.1996.533947","DOIUrl":null,"url":null,"abstract":"Determining line current harmonics in controlled AC/DC power converters, the actual working point given by the average DC voltage and the DC mean current is of significant importance. For good DC smoothing, the consideration of a sufficient control margin in many applications leads to a distinct reduction when evaluating harmonics. To investigate the general case including commutation and DC current ripple, IEEE-Std. 519 as well as the recent FFT-proposal deal with approximated angles. This simplification causes the problem of realization of the required DC mean current in cases of higher DC ripple. To avoid this, a modified version of the selection method is proposed. A comparison of time simulations shows that only this procedure determines line current harmonics with sufficient small error.","PeriodicalId":122944,"journal":{"name":"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1996.533947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Determining line current harmonics in controlled AC/DC power converters, the actual working point given by the average DC voltage and the DC mean current is of significant importance. For good DC smoothing, the consideration of a sufficient control margin in many applications leads to a distinct reduction when evaluating harmonics. To investigate the general case including commutation and DC current ripple, IEEE-Std. 519 as well as the recent FFT-proposal deal with approximated angles. This simplification causes the problem of realization of the required DC mean current in cases of higher DC ripple. To avoid this, a modified version of the selection method is proposed. A comparison of time simulations shows that only this procedure determines line current harmonics with sufficient small error.
受控交直流变换器中工作点确定线路电流谐波的意义
确定被控交/直流电源变换器的线路电流谐波,由直流平均电压和直流平均电流给出的实际工作点具有重要意义。对于良好的直流平滑,在许多应用中考虑足够的控制余量会导致在评估谐波时明显减少。研究一般情况下,包括换流和直流纹波,IEEE-Std。519以及最近的fft提案处理近似角度。这种简化导致了在直流纹波较大的情况下实现所需的直流平均电流的问题。为了避免这种情况,提出了一种改进的选择方法。时间仿真的对比表明,仅用该方法即可确定线路电流谐波,且误差足够小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信