Electro-optical sensor for shielding-effectiveness measurements of motor-control-unit enclosures

L. Thiele, R. Geise
{"title":"Electro-optical sensor for shielding-effectiveness measurements of motor-control-unit enclosures","authors":"L. Thiele, R. Geise","doi":"10.1109/ISEMC.2011.6038294","DOIUrl":null,"url":null,"abstract":"This paper presents shielding effectiveness measurements of a small enclosure for motor control units in two frequency ranges from 10 kHz to 200 MHz and 200 MHz up to 3 GHz. Measurements take place in two different measurement environments, namely in a TEM-cell and in front of an absorber-covered wall. Due to little space in partly equipped enclosures, small field probes have to be used. This paper shows measurements done with a small electro-optical E-field sensor, which is used in various configurations according to the dynamic range. The measurements are done with the enclosures fully equipped with their electronic devices. Thus, the results presented here give a good overview of most realistic, possible EMC-threats of such control-units, which can hardly be obtained from simulations. The main aim of this paper is to compare the modifications of the sensor system and the two frequency ranges. Finally it is shown, that common shielded enclosures provide sufficient shielding effectiveness in the relevant frequency ranges.","PeriodicalId":440959,"journal":{"name":"2011 IEEE International Symposium on Electromagnetic Compatibility","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2011.6038294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents shielding effectiveness measurements of a small enclosure for motor control units in two frequency ranges from 10 kHz to 200 MHz and 200 MHz up to 3 GHz. Measurements take place in two different measurement environments, namely in a TEM-cell and in front of an absorber-covered wall. Due to little space in partly equipped enclosures, small field probes have to be used. This paper shows measurements done with a small electro-optical E-field sensor, which is used in various configurations according to the dynamic range. The measurements are done with the enclosures fully equipped with their electronic devices. Thus, the results presented here give a good overview of most realistic, possible EMC-threats of such control-units, which can hardly be obtained from simulations. The main aim of this paper is to compare the modifications of the sensor system and the two frequency ranges. Finally it is shown, that common shielded enclosures provide sufficient shielding effectiveness in the relevant frequency ranges.
电机控制单元外壳屏蔽效能测量用光电传感器
本文介绍了用于电机控制单元的小型外壳在10 kHz至200 MHz和200 MHz至3 GHz两个频率范围内的屏蔽效能测量。测量在两种不同的测量环境中进行,即在tem细胞中和在吸收剂覆盖的墙壁前。由于部分装备的外壳空间很小,因此必须使用小型现场探头。本文介绍了一种小型的光电电场传感器,它可以根据动态范围在不同的配置中使用。测量是在配备了电子设备的外壳中完成的。因此,本文给出的结果很好地概述了此类控制单元的最现实,可能的emc威胁,这很难从模拟中获得。本文的主要目的是比较传感器系统和两个频率范围的修改。最后表明,普通屏蔽外壳在相关频率范围内提供足够的屏蔽效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信