P. Moravec, R. Grill, J. Franc, P. Hoeschl, E. Belas
{"title":"Transport properties of p-Hg1-xCdxTe (x = 0.22)","authors":"P. Moravec, R. Grill, J. Franc, P. Hoeschl, E. Belas","doi":"10.1117/12.368373","DOIUrl":null,"url":null,"abstract":"Measurements of the Hall coefficient and conductivity of not intentionally doped p-Hg1-xCdxTe samples at temperatures 4.2-300K are reported. A theoretical approximation of experimental data based on a solution of the electronic Boltzmann transport equation and subsequent fitting procedure is done giving a very good agreement between the experiment and calculation. The measurements are analyzed in the full temperature interval simultaneously using the same relevant model parameters in the doping, intrinsic and intermediate region as well. The three- acceptor-level model for one divalent acceptor and one monovalent residual acceptor is discussed. The precision of model parameters determined by this way is analyzed. A novel method to check the sample homogeneity is suggested.","PeriodicalId":276773,"journal":{"name":"Material Science and Material Properties for Infrared Optics","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Material Science and Material Properties for Infrared Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.368373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Measurements of the Hall coefficient and conductivity of not intentionally doped p-Hg1-xCdxTe samples at temperatures 4.2-300K are reported. A theoretical approximation of experimental data based on a solution of the electronic Boltzmann transport equation and subsequent fitting procedure is done giving a very good agreement between the experiment and calculation. The measurements are analyzed in the full temperature interval simultaneously using the same relevant model parameters in the doping, intrinsic and intermediate region as well. The three- acceptor-level model for one divalent acceptor and one monovalent residual acceptor is discussed. The precision of model parameters determined by this way is analyzed. A novel method to check the sample homogeneity is suggested.