{"title":"Development of a Shock & Vibration Spec for 300mm Wafer AMHS Handling","authors":"J. Steele, T. Biswas","doi":"10.1109/ASMC.2006.1638762","DOIUrl":null,"url":null,"abstract":"In this work, a technique is presented for establishing and verifying safe vibration and shock limits for preventing cross-slotting of 300mm wafers in FOUPs during AMHS handling. This technique includes establishing the safe limits using a shaker table, calibrating these limits for a particular portable accelerometer, and then using this portable accelerometer to check an AMHS for compliance to these limits","PeriodicalId":407645,"journal":{"name":"The 17th Annual SEMI/IEEE ASMC 2006 Conference","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 17th Annual SEMI/IEEE ASMC 2006 Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASMC.2006.1638762","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
In this work, a technique is presented for establishing and verifying safe vibration and shock limits for preventing cross-slotting of 300mm wafers in FOUPs during AMHS handling. This technique includes establishing the safe limits using a shaker table, calibrating these limits for a particular portable accelerometer, and then using this portable accelerometer to check an AMHS for compliance to these limits