An integrated common-mode feedback topology for multi-frequency bioimpedance imaging

M. Rahal, A. Demosthenous, R. Bayford
{"title":"An integrated common-mode feedback topology for multi-frequency bioimpedance imaging","authors":"M. Rahal, A. Demosthenous, R. Bayford","doi":"10.1109/ESSCIRC.2009.5325943","DOIUrl":null,"url":null,"abstract":"One of the key limitations in medical impedance imaging and bio-impedance measurements is common-mode errors. We present an integrated common-mode feedback topology which reduces these errors for use in a bio-imaging system for in-vivo monitoring of neonate lung function (10–200 kHz current injection frequency). A frequency-selective feedback network is described which reduces the common-mode voltage due to electrode impedance mismatch at the input of the differential amplifier. The theory and key design blocks are presented. The circuit was implemented in a 5-V 0.35-µm CMOS technology, occupying an area of 0.75 mm2 and dissipating about 20 mW. Experiments were conducted using, an RC model of the electrodes, and ECG electrodes on the forearm to demonstrate the working of the integrated circuit. Measured results show that the common-mode signal is reduced by 85%, 75%, 70% and 65% at 10kHz, 50kHz, 100 kHz and 200 kHz, respectively.","PeriodicalId":258889,"journal":{"name":"2009 Proceedings of ESSCIRC","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Proceedings of ESSCIRC","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESSCIRC.2009.5325943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

One of the key limitations in medical impedance imaging and bio-impedance measurements is common-mode errors. We present an integrated common-mode feedback topology which reduces these errors for use in a bio-imaging system for in-vivo monitoring of neonate lung function (10–200 kHz current injection frequency). A frequency-selective feedback network is described which reduces the common-mode voltage due to electrode impedance mismatch at the input of the differential amplifier. The theory and key design blocks are presented. The circuit was implemented in a 5-V 0.35-µm CMOS technology, occupying an area of 0.75 mm2 and dissipating about 20 mW. Experiments were conducted using, an RC model of the electrodes, and ECG electrodes on the forearm to demonstrate the working of the integrated circuit. Measured results show that the common-mode signal is reduced by 85%, 75%, 70% and 65% at 10kHz, 50kHz, 100 kHz and 200 kHz, respectively.
用于多频生物阻抗成像的集成共模反馈拓扑
医学阻抗成像和生物阻抗测量的主要限制之一是共模误差。我们提出了一个集成的共模反馈拓扑结构,它减少了这些误差,用于用于新生儿肺功能体内监测的生物成像系统(10-200 kHz电流注射频率)。描述了一种频率选择反馈网络,该网络降低了差分放大器输入端由于电极阻抗失配引起的共模电压。介绍了该系统的原理和关键设计模块。该电路采用5 v 0.35µm CMOS技术实现,占地面积为0.75 mm2,功耗约为20 mW。实验采用电极的RC模型和前臂上的ECG电极来演示集成电路的工作原理。实测结果表明,在10kHz、50kHz、100khz和200khz时,共模信号分别减少85%、75%、70%和65%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信