Harmonic active power flow in low and medium voltage distribution systems

J. Lundquist, M. Bollen
{"title":"Harmonic active power flow in low and medium voltage distribution systems","authors":"J. Lundquist, M. Bollen","doi":"10.1109/PESW.2000.847338","DOIUrl":null,"url":null,"abstract":"This paper shows the principles of how the harmonic active power flow in radial low and medium voltage distribution systems varies due to the interaction between loads and the power system. The interaction is due to the change in source impedance caused by e.g. harmonic filters or capacitor banks and a mix of single and three phase nonlinear and linear loads. The active harmonic power flow in a certain point in a power system, with nonlinear loads, in most cases does not represent the actual flow to the loads in the downstream system. The harmonic active power is partly or completely included in the fundamental active power, depending on the mix of loads. Some basic examples are shown in addition with measurements from a low voltage system equipped with harmonic filters, feeding a nonlinear load.","PeriodicalId":286352,"journal":{"name":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","volume":"342 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2000.847338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This paper shows the principles of how the harmonic active power flow in radial low and medium voltage distribution systems varies due to the interaction between loads and the power system. The interaction is due to the change in source impedance caused by e.g. harmonic filters or capacitor banks and a mix of single and three phase nonlinear and linear loads. The active harmonic power flow in a certain point in a power system, with nonlinear loads, in most cases does not represent the actual flow to the loads in the downstream system. The harmonic active power is partly or completely included in the fundamental active power, depending on the mix of loads. Some basic examples are shown in addition with measurements from a low voltage system equipped with harmonic filters, feeding a nonlinear load.
中、低压配电系统中的谐波有功潮流
本文阐述了径向中、低压配电系统谐波有功潮流在负荷与电力系统相互作用下的变化原理。这种相互作用是由于源阻抗的变化引起的,例如谐波滤波器或电容器组,以及单相和三相非线性和线性负载的混合。在具有非线性负荷的电力系统中,某一点的有功谐波潮流在大多数情况下并不代表下游系统中负荷的实际潮流。谐波有功功率部分或全部包含在基波有功功率中,这取决于负载的混合情况。此外,还给出了一些基本的例子,并从一个装有谐波滤波器的低压系统中测量了非线性负载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信