{"title":"Medium-Voltage Switchgear Low Temperature Dielectric Performance when Using Alternative Insulating Gas to SF6","authors":"J. Moore, Rahul Jain, James F. Fargo","doi":"10.1109/td43745.2022.9817002","DOIUrl":null,"url":null,"abstract":"The use and emissions of SF<inf>6</inf> are increasingly being reduced and regulated. There are green designs for S&C Vista® Underground Distribution Switchgear (Vista) that use a mixture of C4 Fluoronitrile gas and Carbon Dioxide (CO<inf>2</inf>) instead of SF<inf>6</inf>. These designs were tested for Power Frequency Withstand (PFWS) and Basic Impulse Level (BIL) at temperatures at and below <tex>$\\mathbf{-30^{\\circ}C}$</tex>, the prevailing standard for underground distribution switchgear. The calculated Dew Point of the mixture is <tex>$\\mathbf{-37.2^{\\circ}C}$</tex>. The results indicate that the gear meets PFWS at <tex>$\\mathbf{-50^{\\circ}C}$</tex> for all voltages, and BIL at <tex>$\\mathbf{-50^{\\circ}C}$</tex> for <tex>$\\mathbf{15 kV}$</tex> class and at <tex>$\\mathbf{-30^{\\circ}C}$</tex> for <tex>$\\mathbf{25kV}$</tex> and <tex>$\\mathbf{35 kV}$</tex> class. BIL at <tex>$\\mathbf{-50^{\\circ}C}$</tex> for 27 and 38 KV classes require a 10% derating.","PeriodicalId":241987,"journal":{"name":"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/td43745.2022.9817002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The use and emissions of SF6 are increasingly being reduced and regulated. There are green designs for S&C Vista® Underground Distribution Switchgear (Vista) that use a mixture of C4 Fluoronitrile gas and Carbon Dioxide (CO2) instead of SF6. These designs were tested for Power Frequency Withstand (PFWS) and Basic Impulse Level (BIL) at temperatures at and below $\mathbf{-30^{\circ}C}$, the prevailing standard for underground distribution switchgear. The calculated Dew Point of the mixture is $\mathbf{-37.2^{\circ}C}$. The results indicate that the gear meets PFWS at $\mathbf{-50^{\circ}C}$ for all voltages, and BIL at $\mathbf{-50^{\circ}C}$ for $\mathbf{15 kV}$ class and at $\mathbf{-30^{\circ}C}$ for $\mathbf{25kV}$ and $\mathbf{35 kV}$ class. BIL at $\mathbf{-50^{\circ}C}$ for 27 and 38 KV classes require a 10% derating.
使用SF6替代绝缘气体时的中压开关柜低温介电性能
SF6的使用和排放正日益减少和受到监管。S&C Vista®地下配电开关设备(Vista)采用绿色设计,使用C4氟腈气体和二氧化碳(CO2)的混合物而不是SF6。这些设计在低于$\mathbf{-30^{\circ}C}$的温度下进行了工频耐压(PFWS)和基本脉冲电平(BIL)测试,这是地下配电开关设备的现行标准。计算得到混合物的露点为$\mathbf{-37.2^{\circ}C}$。结果表明,该装置在所有电压下均满足PFWS值$\mathbf{-50^{\circ}C}$,在$\mathbf{15 kV}$等级下满足PFWS值$\mathbf{-50^{\circ}C}$,在$\mathbf{25kV}$和$\mathbf{35 kV}$等级下满足PFWS值$\mathbf{-30^{\circ} $。$\mathbf{-50^{\circ}C}$为27和38 KV等级的BIL需要10%的降额。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信