Rehabilitation exercise monitoring device for knee osteoarthritis patients

Nur Amirah Ishak, M. M. Addi
{"title":"Rehabilitation exercise monitoring device for knee osteoarthritis patients","authors":"Nur Amirah Ishak, M. M. Addi","doi":"10.1109/ICCEREC.2017.8226715","DOIUrl":null,"url":null,"abstract":"Osteoarthritis (OA) is a joint disease that causes disability and joint irritation. Knee OA is known to be one of the most common OA type that happen in patient. The safest treatment to reduce the pain is by having the rehabilitation exercises. Normally, patients of knee OA will undergo prescribed physical activity treatment in the hospital using sophisticated and expensive rehabilitation equipment with monitoring by specialist. Another alternative is to conduct the rehabilitation exercises at home. However, improper exercise movement may cause further injury to the patient when doing it at home. In this project a rehabilitation exercise monitoring device for knee OA is proposed. Two accelerometers are used to obtain the data of body motion from the thigh and shank. Arduino is used to process the signal obtain from the accelerometers for exercise classification and detection of incorrect exercise movement with the use LEDs as indicators. Subject conducted two types of exercise which include the Short Arc Exercise (SAE) and Straight Leg Raise (SLR) to test the detection accuracy of the system. The system was able to detect both SAE and SLR exercises with 100% accuracy. However, the system was only able to detect improper exercises movement for SAE (100%) but with a lower accuracy to detect for SLR exercise, showing the lowest accuracy for subject A when the hip joint external rotation movement was out of the allowable range and when knee is not fully extended. Lastly, the average angle for improper exercises movement was able to determine with some variation angle for each error label. By implementing the rehabilitation monitoring system, specialist are able to monitor (offline) the performance of their patient when conducting the rehabilitation activities at home and the patient will able to get feedback their exercise movement.","PeriodicalId":328054,"journal":{"name":"2017 International Conference on Control, Electronics, Renewable Energy and Communications (ICCREC)","volume":"112 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Control, Electronics, Renewable Energy and Communications (ICCREC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEREC.2017.8226715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Osteoarthritis (OA) is a joint disease that causes disability and joint irritation. Knee OA is known to be one of the most common OA type that happen in patient. The safest treatment to reduce the pain is by having the rehabilitation exercises. Normally, patients of knee OA will undergo prescribed physical activity treatment in the hospital using sophisticated and expensive rehabilitation equipment with monitoring by specialist. Another alternative is to conduct the rehabilitation exercises at home. However, improper exercise movement may cause further injury to the patient when doing it at home. In this project a rehabilitation exercise monitoring device for knee OA is proposed. Two accelerometers are used to obtain the data of body motion from the thigh and shank. Arduino is used to process the signal obtain from the accelerometers for exercise classification and detection of incorrect exercise movement with the use LEDs as indicators. Subject conducted two types of exercise which include the Short Arc Exercise (SAE) and Straight Leg Raise (SLR) to test the detection accuracy of the system. The system was able to detect both SAE and SLR exercises with 100% accuracy. However, the system was only able to detect improper exercises movement for SAE (100%) but with a lower accuracy to detect for SLR exercise, showing the lowest accuracy for subject A when the hip joint external rotation movement was out of the allowable range and when knee is not fully extended. Lastly, the average angle for improper exercises movement was able to determine with some variation angle for each error label. By implementing the rehabilitation monitoring system, specialist are able to monitor (offline) the performance of their patient when conducting the rehabilitation activities at home and the patient will able to get feedback their exercise movement.
膝关节骨关节炎患者康复运动监测装置
骨关节炎(OA)是一种导致残疾和关节刺激的关节疾病。膝关节骨性关节炎是最常见的骨性关节炎之一。减轻疼痛最安全的方法是进行康复训练。通常情况下,膝关节OA患者会在医院接受规定的身体活动治疗,使用复杂而昂贵的康复设备,并由专家监测。另一种选择是在家进行康复训练。然而,在家中进行不当的运动动作可能会对患者造成进一步的伤害。本课题设计了一种膝关节OA康复运动监测装置。两个加速度计用于从大腿和小腿获取身体运动数据。使用Arduino对加速度计获得的信号进行处理,进行运动分类,检测不正确的运动动作,使用led作为指示器。受试者进行了短弧运动(SAE)和直腿抬高(SLR)两种类型的运动来测试系统的检测精度。该系统能够以100%的准确率检测SAE和SLR演习。然而,该系统仅能够检测SAE(100%)的不当运动,而检测单反运动的准确性较低,当髋关节外旋运动超出允许范围和膝关节未完全伸展时,受试者a的准确性最低。最后,通过对每个误差标签进行一定角度的变化,确定了不正确运动的平均角度。通过实施康复监测系统,专家能够(离线)监测患者在家中进行康复活动时的表现,患者将能够获得他们的运动反馈。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信