Studi Rekonfigurasi Sistem Distribusi Pada Jaringan 20 kV Dengan Metode Simple Branch Exchange Pada Penyulang Cempaka

Fathur Nureza Aksan, Samsurizal
{"title":"Studi Rekonfigurasi Sistem Distribusi Pada Jaringan 20 kV Dengan Metode Simple Branch Exchange Pada Penyulang Cempaka","authors":"Fathur Nureza Aksan, Samsurizal","doi":"10.55893/epsilon.v19i2.64","DOIUrl":null,"url":null,"abstract":"The increasing electric energy consumption must be balanced with good electricity network quality. To overcome this, we need a distribution network reconfiguration. Reconfiguration in power distribution network is done to improve power distribution network quality. Problem that exist in the radial distribution network is power losses. To minimize the power losses can be overcome by compensating capacitor. Done by determining the location of capacitors in distribution networks. With that the capacitor compensates the distribution network is more effective and efficient in distributing power. In this research discusses the network reconfiguration using simple branch exchange method to reduce power losses in radial distribution networks. The reconfiguration method was carried out with the help of the Electrical Transient Analysis Program (ETAP) 12.6.0 software and has been tested by PT REKAYASA INDUSTRI and PLN Area South Kalimantan on the 20 kV distribution system of Cempaka feeder, South Kalimantan. With this reconfiguration, the voltage drop that occurs on several buses, especially bus 37 and 44, has a voltage drop of up to 95.03% to 95.31% with an average drop voltage of 95.1%, which means the average voltage drop. each feeder is ableto send electricity to consumers properly.","PeriodicalId":320715,"journal":{"name":"EPSILON: Journal of Electrical Engineering and Information Technology","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EPSILON: Journal of Electrical Engineering and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55893/epsilon.v19i2.64","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing electric energy consumption must be balanced with good electricity network quality. To overcome this, we need a distribution network reconfiguration. Reconfiguration in power distribution network is done to improve power distribution network quality. Problem that exist in the radial distribution network is power losses. To minimize the power losses can be overcome by compensating capacitor. Done by determining the location of capacitors in distribution networks. With that the capacitor compensates the distribution network is more effective and efficient in distributing power. In this research discusses the network reconfiguration using simple branch exchange method to reduce power losses in radial distribution networks. The reconfiguration method was carried out with the help of the Electrical Transient Analysis Program (ETAP) 12.6.0 software and has been tested by PT REKAYASA INDUSTRI and PLN Area South Kalimantan on the 20 kV distribution system of Cempaka feeder, South Kalimantan. With this reconfiguration, the voltage drop that occurs on several buses, especially bus 37 and 44, has a voltage drop of up to 95.03% to 95.31% with an average drop voltage of 95.1%, which means the average voltage drop. each feeder is ableto send electricity to consumers properly.
用Cempaka倒带上简单的Branch交换方法对20 kV网络的配送系统重新配置研究
不断增长的电能消耗必须与良好的电网质量相平衡。为了克服这个问题,我们需要重新配置分销网络。对配电网进行重构是为了提高配电网质量。径向配电网存在的主要问题是功率损耗。为了使功率损失最小化,可以通过补偿电容器来克服。通过确定配电网中电容器的位置来完成。因此,电容器补偿配电网的配电效率更高。本文讨论了采用简单支路交换法对径向配电网进行重构,以降低电网的功率损耗。利用ETAP 12.6.0软件对重构方法进行了分析,并通过PT REKAYASA INDUSTRI和PLN Area South Kalimantan对南加里曼丹Cempaka馈线20 kV配电系统进行了测试。通过这种重新配置,在几条母线上发生的电压降,特别是母线37和44,其电压降高达95.03% ~ 95.31%,平均电压降为95.1%,即平均电压降。每个馈线都能正确地向用户输送电力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信