An improved echo tracking algorithm for arterial distensibility measurements

J. Joseph, V. Jayashankar
{"title":"An improved echo tracking algorithm for arterial distensibility measurements","authors":"J. Joseph, V. Jayashankar","doi":"10.1109/ICBPE.2009.5384091","DOIUrl":null,"url":null,"abstract":"Arterial distensibility is often measured by non-invasively detecting the change in artery diameter over a cardiac cycle. Traditional methods using B-mode images require considerable processing power and time. Here we present a method to extract the distensibility waveform from RF signals obtained by ultrasound interrogation of the carotid artery. We propose an automatic method that uses an adaptive threshold to track the desired number of echoes and measure the artery diameter accurately. The algorithm could be used along with single element transducer based ultrasound measurement systems as well as B-mode scanners. The performance is analyzed using data obtained using phantom models of the artery as well as from human volunteers.","PeriodicalId":384086,"journal":{"name":"2009 International Conference on Biomedical and Pharmaceutical Engineering","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Biomedical and Pharmaceutical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBPE.2009.5384091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Arterial distensibility is often measured by non-invasively detecting the change in artery diameter over a cardiac cycle. Traditional methods using B-mode images require considerable processing power and time. Here we present a method to extract the distensibility waveform from RF signals obtained by ultrasound interrogation of the carotid artery. We propose an automatic method that uses an adaptive threshold to track the desired number of echoes and measure the artery diameter accurately. The algorithm could be used along with single element transducer based ultrasound measurement systems as well as B-mode scanners. The performance is analyzed using data obtained using phantom models of the artery as well as from human volunteers.
一种用于动脉扩张性测量的改进回声跟踪算法
动脉扩张性通常是通过无创检测一个心动周期内动脉直径的变化来测量的。使用b模式图像的传统方法需要相当大的处理能力和时间。本文提出了一种从超声检查颈动脉射频信号中提取扩张性波形的方法。我们提出了一种使用自适应阈值跟踪所需回波数并准确测量动脉直径的自动方法。该算法可以与基于单元件换能器的超声测量系统以及b型扫描仪一起使用。通过使用动脉模型和人类志愿者获得的数据来分析其性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信