Concurrent Validity and Inter-Rater Reliability of Hand-Held Measurements of Maximal Sprint Speed

IF 1
Bartosz Zając, Paulina Gaj, J. Zięba
{"title":"Concurrent Validity and Inter-Rater Reliability of Hand-Held Measurements of Maximal Sprint Speed","authors":"Bartosz Zając, Paulina Gaj, J. Zięba","doi":"10.5604/01.3001.0016.1225","DOIUrl":null,"url":null,"abstract":"Background: Maximal sprinting speed (MSS) is an essential component of success in many sports. Currently, many systems are used to accurately evaluate athletes’ MSS, including laser or radar guns, single- or dual-beam photocells, high-speed cameras, and high-frequency global positioning systems. However, the cost of these devices may be an obstacle to their implementation into practice. The least expensive but most likely less accurate alternative method of MSS evaluation is the hand-held time measurement of a 30m flying-start sprint. Therefore, the aim of the study was to assess the concurrent validity and inter-rater reliability o the hand-held method of MSS measurement. Materials and Methods: The study involved 3 experienced raters and 18 amateur runners. Runners performed 2-3 trials of the 30m maximal flying-start sprint. In total, 40 observations were collected. Each sprint time was measured simultaneously by raters using a hand-held stopwatch and an electronic timing system. Criterion validity (hand-held vs. electronic timing) was assessed using linear regression analysis. Inter-rater reliability between hand-held timers was evaluated using interclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC). Results: Results showed that single and average hand-held methods are affected by -0.17 to -0.07m·s-1 (-2.5 to -1.6%) and -0.12m·s- 1 (-1.7%) errors, respectively. Linear regression analysis parameters (free parameter not statistically significant, directional coefficient 0.994-1.057, standard error of estimation 0.073-0.125, R2 0.981-0.994) indicated statistically excellent absolute agreement between a hand-held (single and average) and electronic timing. ICCs of 0.980-0.994, SEM of 0.12m·s-1 (1.87%), and MDC of 0.34m·s-1 (5.18%) indicated statistically excellent absolute agreement and consistency for single and average measurements between hand-held timers. Conclusion: The proposed manual method of MSS measurement underestimates athletes’ speed performance. Moreover, the hand-held 30m flying-start sprint time measurement is affected by a 2% error, and a minimum 5% time change in an individual athlete demonstrates that the change is not simply attributable to measurement error.\n\n","PeriodicalId":223482,"journal":{"name":"Journal of Kinesiology and Exercise Sciences","volume":"17 1","pages":"0"},"PeriodicalIF":1.0000,"publicationDate":"2022-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Kinesiology and Exercise Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0016.1225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Maximal sprinting speed (MSS) is an essential component of success in many sports. Currently, many systems are used to accurately evaluate athletes’ MSS, including laser or radar guns, single- or dual-beam photocells, high-speed cameras, and high-frequency global positioning systems. However, the cost of these devices may be an obstacle to their implementation into practice. The least expensive but most likely less accurate alternative method of MSS evaluation is the hand-held time measurement of a 30m flying-start sprint. Therefore, the aim of the study was to assess the concurrent validity and inter-rater reliability o the hand-held method of MSS measurement. Materials and Methods: The study involved 3 experienced raters and 18 amateur runners. Runners performed 2-3 trials of the 30m maximal flying-start sprint. In total, 40 observations were collected. Each sprint time was measured simultaneously by raters using a hand-held stopwatch and an electronic timing system. Criterion validity (hand-held vs. electronic timing) was assessed using linear regression analysis. Inter-rater reliability between hand-held timers was evaluated using interclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC). Results: Results showed that single and average hand-held methods are affected by -0.17 to -0.07m·s-1 (-2.5 to -1.6%) and -0.12m·s- 1 (-1.7%) errors, respectively. Linear regression analysis parameters (free parameter not statistically significant, directional coefficient 0.994-1.057, standard error of estimation 0.073-0.125, R2 0.981-0.994) indicated statistically excellent absolute agreement between a hand-held (single and average) and electronic timing. ICCs of 0.980-0.994, SEM of 0.12m·s-1 (1.87%), and MDC of 0.34m·s-1 (5.18%) indicated statistically excellent absolute agreement and consistency for single and average measurements between hand-held timers. Conclusion: The proposed manual method of MSS measurement underestimates athletes’ speed performance. Moreover, the hand-held 30m flying-start sprint time measurement is affected by a 2% error, and a minimum 5% time change in an individual athlete demonstrates that the change is not simply attributable to measurement error.
手持最大冲刺速度测量的并发效度和信度
背景:在许多运动中,最大冲刺速度(MSS)是成功的重要组成部分。目前,许多系统用于准确评估运动员的MSS,包括激光或雷达枪、单光束或双光束光电池、高速摄像机和高频全球定位系统。然而,这些设备的成本可能是它们付诸实践的一个障碍。最便宜但最不准确的评估MSS的替代方法是手持式30米起跑冲刺时间测量。因此,本研究的目的是评估手持MSS测量方法的并发效度和量表间信度。材料与方法:研究对象为3名经验丰富的评分员和18名业余跑步爱好者。选手们进行了2-3次30米极限起跑冲刺。总共收集了40项观察结果。每次冲刺时间由评分员使用手持秒表和电子计时系统同时测量。使用线性回归分析评估标准效度(手持式与电子计时)。使用类间相关系数(ICCs)、测量标准误差(SEM)和最小可检测变化(MDC)来评估手持计时器之间的等级间可靠性。结果:结果表明,单手法和平均手握法的误差分别为-0.17 ~ -0.07m·s-1(-2.5 ~ -1.6%)和-0.12m·s- 1(-1.7%)。线性回归分析参数(自由参数无统计学意义,方向系数0.994 ~ 1.057,估计标准误差0.073 ~ 0.125,R2 0.981 ~ 0.994)表明手持式(单次和平均)与电子计时具有统计学上极好的绝对一致性。ICCs值为0.980 ~ 0.994,SEM值为0.12m·s-1 (1.87%), MDC值为0.34m·s-1(5.18%),表明手持计时器单次测量和平均测量在统计学上具有极好的绝对一致性。结论:提出的人工MSS测量方法低估了运动员的速度表现。此外,手持30米飞跑起跑的冲刺时间测量受到2%误差的影响,单个运动员至少5%的时间变化表明这种变化不仅仅是由于测量误差造成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书