Silicon bolometer and micro variable infrared filter for CO/sub 2/ measurement

H. Hara, N. Kishi, H. Iwaoka
{"title":"Silicon bolometer and micro variable infrared filter for CO/sub 2/ measurement","authors":"H. Hara, N. Kishi, H. Iwaoka","doi":"10.1109/OMEMS.2000.879664","DOIUrl":null,"url":null,"abstract":"We have developed silicon bolometers fabricated on an SOI wafer by bulk micromachining and a micro variable infrared filter, and have investigated CO/sub 2/ measurement using these elements as an NDIR system. The bolometer has a measured D* (1100 K, 10 Hz, 1 Hz) of 1.1/spl times/10/sup 8/ cmHz/sup 1/2//W. Two bolometers were combined with a micro variable infrared filter tuned to two different wavelengths: the CO/sub 2/ absorption band and the reference band. The two-wavelength NDIR system for combining these elements with the conventional infrared source was able to measure the concentration of CO/sub 2/ with the measurement reproducibility 3 /spl sigma/ of /spl plusmn/3.6% of the measured value or less between the concentrations of 0 ppm and 5000 ppm.","PeriodicalId":148819,"journal":{"name":"2000 IEEE/LEOS International Conference on Optical MEMS (Cat. No.00EX399)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE/LEOS International Conference on Optical MEMS (Cat. No.00EX399)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMEMS.2000.879664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

We have developed silicon bolometers fabricated on an SOI wafer by bulk micromachining and a micro variable infrared filter, and have investigated CO/sub 2/ measurement using these elements as an NDIR system. The bolometer has a measured D* (1100 K, 10 Hz, 1 Hz) of 1.1/spl times/10/sup 8/ cmHz/sup 1/2//W. Two bolometers were combined with a micro variable infrared filter tuned to two different wavelengths: the CO/sub 2/ absorption band and the reference band. The two-wavelength NDIR system for combining these elements with the conventional infrared source was able to measure the concentration of CO/sub 2/ with the measurement reproducibility 3 /spl sigma/ of /spl plusmn/3.6% of the measured value or less between the concentrations of 0 ppm and 5000 ppm.
用于CO/sub /测量的硅测热计和微可变红外滤波器
我们已经开发了在SOI晶圆上通过体微加工和微可变红外滤波器制造的硅热计,并研究了使用这些元件作为NDIR系统的CO/sub 2/测量。辐射热计的测量D* (1100k, 10hz, 1hz)为1.1/spl倍/10/sup 8/ cmHz/sup 1/2//W。两个测辐射热计与一个微可变红外滤光片相结合,调谐到两个不同的波长:CO/sub - 2/吸收波段和参考波段。将这些元素与传统红外光源结合的双波长NDIR系统能够测量CO/sub / 2/浓度,测量重现性为3 /spl sigma/ of /spl plusmn/3.6%,测量值在0 ppm到5000 ppm之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信