Body composition of female office workers compared with infrared reflection measurement, bioimpedance analysis and calipermetry

C. Raschka, O-sung Kwon, H. Koch
{"title":"Body composition of female office workers compared with infrared reflection measurement, bioimpedance analysis and calipermetry","authors":"C. Raschka, O-sung Kwon, H. Koch","doi":"10.12697/poa.2022.31.2.03","DOIUrl":null,"url":null,"abstract":"There are currently many different anthropometric methods for determining the individual body fat percentage, as well as almost as many variants of bioelectric impedance analysis (BIA) and only a single method of infrared reflection measurement (IR) as easily available methods of field research. \nThe present study aims at a simultaneous comparison between calipermetry, IR and BIA. In particular, the question which measurement method could be used as an equivalent method in the event of failure of BIA or IR is investigated. \nThe sample group consisted of 121 female office workers (average age 32.5 ± 9.4 years, average height 164.5 ± 6.3 cm and average weight 60.3 ± 6.8 kg), from the Rhine-Main area. \nThe measurements were previously scheduled and mostly carried out during the lunch break. For anthropometry, 13 skin fat folds were measured with the Accu® Measure Caliper, thigh circumference with a measuring tape, the height with a height measuring device and the body mass on the weight scale. Subsequently, an IR measurement (Futrex®) and a BIA (InBody®) were performed on the same subjects. \nThe parameters of body fat percentage and total body water (in L) were examined. \nStatistical methods were correlation coefficients, Bland-Altman comparison and paired t-test for equivalence. \nFor the women studied, the highest correlation coefficients were in the comparisons between the formulas according to Parízková and Brožek et al. (r = 0.82), as well as for Parízková and Siri (r = 0.82). \nThe correlation coefficient for the IR vs. BIA comparison was r = 0.92. \nA key result of the present study was the finding that the investigated methods in a female study group could not be substituted in an equivalent way.","PeriodicalId":173079,"journal":{"name":"Papers on Anthropology","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Papers on Anthropology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12697/poa.2022.31.2.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

There are currently many different anthropometric methods for determining the individual body fat percentage, as well as almost as many variants of bioelectric impedance analysis (BIA) and only a single method of infrared reflection measurement (IR) as easily available methods of field research. The present study aims at a simultaneous comparison between calipermetry, IR and BIA. In particular, the question which measurement method could be used as an equivalent method in the event of failure of BIA or IR is investigated. The sample group consisted of 121 female office workers (average age 32.5 ± 9.4 years, average height 164.5 ± 6.3 cm and average weight 60.3 ± 6.8 kg), from the Rhine-Main area. The measurements were previously scheduled and mostly carried out during the lunch break. For anthropometry, 13 skin fat folds were measured with the Accu® Measure Caliper, thigh circumference with a measuring tape, the height with a height measuring device and the body mass on the weight scale. Subsequently, an IR measurement (Futrex®) and a BIA (InBody®) were performed on the same subjects. The parameters of body fat percentage and total body water (in L) were examined. Statistical methods were correlation coefficients, Bland-Altman comparison and paired t-test for equivalence. For the women studied, the highest correlation coefficients were in the comparisons between the formulas according to Parízková and Brožek et al. (r = 0.82), as well as for Parízková and Siri (r = 0.82). The correlation coefficient for the IR vs. BIA comparison was r = 0.92. A key result of the present study was the finding that the investigated methods in a female study group could not be substituted in an equivalent way.
用红外反射法、生物阻抗法和测径法比较女性上班族的身体成分
目前有许多不同的人体测量方法来确定个体体脂百分比,以及几乎同样多的变体生物电阻抗分析(BIA)和红外反射测量(IR)的单一方法作为容易获得的实地研究方法。本研究旨在同时比较测径法、IR法和BIA法。特别探讨了在BIA或IR失效时,哪种测量方法可以作为等效方法的问题。样本组包括121名来自莱茵-美因地区的女性办公室职员(平均年龄32.5±9.4岁,平均身高164.5±6.3 cm,平均体重60.3±6.8 kg)。这些测量是事先安排好的,而且大多在午休时间进行。在人体测量中,用Accu®Measure卡尺测量13个皮肤脂肪褶皱,用卷尺测量大腿围,用身高测量仪测量身高,在体重秤上测量体重。随后,对同一受试者进行红外测量(Futrex®)和BIA (InBody®)。测定体脂率和总水(L)等指标。统计方法为相关系数、Bland-Altman比较和配对t检验。对于被研究的女性来说,根据Parízková和Brožek等人的公式(r = 0.82)以及Parízková和Siri的公式(r = 0.82)进行比较,相关系数最高。IR与BIA比较的相关系数r = 0.92。本研究的一个关键结果是发现在女性研究组中所调查的方法不能以等效的方式替代。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信