Point-of-use measurement of salivary cortisol levels

M. Yamaguchi, S. Yoshikawa, Y. Tahara, D. Niwa, Yoshikatsu Imai, V. Shetty
{"title":"Point-of-use measurement of salivary cortisol levels","authors":"M. Yamaguchi, S. Yoshikawa, Y. Tahara, D. Niwa, Yoshikatsu Imai, V. Shetty","doi":"10.1109/ICSENS.2009.5398143","DOIUrl":null,"url":null,"abstract":"The objective is to develop a novel methodology to analyze cortisol levels in saliva as an index of neuroendocrine response. In order to realize a portable, rapid and hand held biosensor of cortisol, we proposed an immuno-chromatographic test-strip based biosensor consisting of a disposable test-strip and a monitor. A fabricated disposable type test-strip has a size of 5 × 1.5 × 50 mm3. In order to realize an immuno-chromatographic test-strip, a glucose oxidase (GOD)-cortisol conjugate was newly synthesized, because the speed and selectivity of immunological reactions is particularly attractive as a strategy for molecular recognition of cortisol. The synthesized molecule was identified as the GOD-cortisol conjugate by both its molecular weight and specific detection of cortisol. Three min after addition of GOD enzyme assay solution, a color change reaction at a test line was observed. The R2 value for the calibration curve of the cortisol test strip was 0.95, and the relationship between its reflectance, r, and the cortisol level was r = 0.629 (1−0.232e(−1.78 × cortisol)). The fabricated cortisol biosensor enabled us to analyze cortisol concentrations between 1 – 10 ng/ml within 25 min of dropping a cortisol solution on the test strip. Thus, it is suggested that the cortisol biosensor may possibly be used for point-of-use measurements in hospitals.","PeriodicalId":262591,"journal":{"name":"2009 IEEE Sensors","volume":"214 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2009.5398143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

The objective is to develop a novel methodology to analyze cortisol levels in saliva as an index of neuroendocrine response. In order to realize a portable, rapid and hand held biosensor of cortisol, we proposed an immuno-chromatographic test-strip based biosensor consisting of a disposable test-strip and a monitor. A fabricated disposable type test-strip has a size of 5 × 1.5 × 50 mm3. In order to realize an immuno-chromatographic test-strip, a glucose oxidase (GOD)-cortisol conjugate was newly synthesized, because the speed and selectivity of immunological reactions is particularly attractive as a strategy for molecular recognition of cortisol. The synthesized molecule was identified as the GOD-cortisol conjugate by both its molecular weight and specific detection of cortisol. Three min after addition of GOD enzyme assay solution, a color change reaction at a test line was observed. The R2 value for the calibration curve of the cortisol test strip was 0.95, and the relationship between its reflectance, r, and the cortisol level was r = 0.629 (1−0.232e(−1.78 × cortisol)). The fabricated cortisol biosensor enabled us to analyze cortisol concentrations between 1 – 10 ng/ml within 25 min of dropping a cortisol solution on the test strip. Thus, it is suggested that the cortisol biosensor may possibly be used for point-of-use measurements in hospitals.
唾液皮质醇水平的即时测量
目的是开发一种新的方法来分析唾液中的皮质醇水平作为神经内分泌反应的指标。为了实现一种便携式、快速、手持的皮质醇生物传感器,我们提出了一种基于免疫色谱试纸条的生物传感器,该生物传感器由一次性试纸条和监测器组成。制作的一次性试纸条尺寸为5 × 1.5 × 50 mm3。为了实现免疫层析试纸条,合成了葡萄糖氧化酶(GOD)-皮质醇偶联物,因为免疫反应的速度和选择性特别吸引人作为分子识别皮质醇的策略。合成的分子通过分子量和对皮质醇的特异性检测鉴定为god -皮质醇偶联物。添加GOD酶测定液3 min后,在试验线上观察到变色反应。皮质醇试纸条校准曲线的R2值为0.95,其反射率r与皮质醇水平的关系为r = 0.629(1−0.232e(−1.78 ×皮质醇))。制造的皮质醇生物传感器使我们能够在将皮质醇溶液滴在测试条上25分钟内分析皮质醇浓度在1 - 10 ng/ml之间。因此,建议皮质醇生物传感器可能用于医院的使用点测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信