Short-term influence of LASIK on anterior and posterior corneal asphericity

J. Hou, Yan Wang, T. Zuo, Wei-li Geng, Ying Jin, Xiaoyan Yang, Li-qing Liu
{"title":"Short-term influence of LASIK on anterior and posterior corneal asphericity","authors":"J. Hou, Yan Wang, T. Zuo, Wei-li Geng, Ying Jin, Xiaoyan Yang, Li-qing Liu","doi":"10.3969/J.ISSN.1003-0808.2010.03.019","DOIUrl":null,"url":null,"abstract":"Background Laser in situ keratomileusis (LASIK) is frequently performed to reduce or eliminate myopic refractive error.Some patients complain of a loss of visual function after surgery even when they have 20/20 visual acuity.One of the reasons is the change of asphericity of the cornea.Objective This study attempts to investigate the short-term changes of the anterior and posterior corneal asphericity after LASIK.Methods One hundred and seven myopic eyes of 54 subjects with the equivalent spherical diopter of -1.30 to -7.50 D who have received LASIK were enrolled in this prospective study.The Q-values of the posterior corneal surface for different corneal diameters (6mm,7mm,8mm and 9mm) were measured with Pentacam preoperatively and 1 month postoperatively.The correlations between Q-value,Q change (△Q),and the mean preoperative spherical equivalent refraction (SE),central corneal thickness (CCT),central ablation depth (AD) and residual bed thickness were investigated.Written informed consents were obtained from all the subjects prior to the clinical trial.Results The Q-values of the anterior and posterior corneal surfaces gradually decreased to negative values with the increase of corneal diameter in myopic eyes.Weak correlations were found between the asphericity of the anterior and posterior corneal surfaces from diameters of 6mm,7mm,8mm and 9mm (r=0.227,0.288,0.303,0.389;P=0.019,0.003,0.002 and 0.000,respectively).No statistically significant correlation was found between Q-value and the diopter of refractive error (P>0.05).Both the anterior and posterior corneal Q-values varied toward the positive direction except that in the 9mm area of the posterior corneal surface at postoperative 1 month(t=-1.495,P=0.138).The increase of the anterior corneal asphericity (△Q) was more obvious than that of the posterior corneal surface and showed a positive correlation with ablation depth and a negative correlation with residual bed thickness.However,no statistically significant correlation was seen between △Q and these two parameters in the posterior corneal surface (P>0.05).Conclusion The shape of the anterior and posterior corneal surface shows more prolateness as the increase of corneal diameter in myopic eyes.Both the anterior and the posterior corneal surfaces have an oblate shift within the ablation zone 1 month after LASIK. \n \nKey words: \nmyopia; excimer laser; asphericity; Q-value","PeriodicalId":186994,"journal":{"name":"Chinese Ophthalmic Research","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Ophthalmic Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3969/J.ISSN.1003-0808.2010.03.019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background Laser in situ keratomileusis (LASIK) is frequently performed to reduce or eliminate myopic refractive error.Some patients complain of a loss of visual function after surgery even when they have 20/20 visual acuity.One of the reasons is the change of asphericity of the cornea.Objective This study attempts to investigate the short-term changes of the anterior and posterior corneal asphericity after LASIK.Methods One hundred and seven myopic eyes of 54 subjects with the equivalent spherical diopter of -1.30 to -7.50 D who have received LASIK were enrolled in this prospective study.The Q-values of the posterior corneal surface for different corneal diameters (6mm,7mm,8mm and 9mm) were measured with Pentacam preoperatively and 1 month postoperatively.The correlations between Q-value,Q change (△Q),and the mean preoperative spherical equivalent refraction (SE),central corneal thickness (CCT),central ablation depth (AD) and residual bed thickness were investigated.Written informed consents were obtained from all the subjects prior to the clinical trial.Results The Q-values of the anterior and posterior corneal surfaces gradually decreased to negative values with the increase of corneal diameter in myopic eyes.Weak correlations were found between the asphericity of the anterior and posterior corneal surfaces from diameters of 6mm,7mm,8mm and 9mm (r=0.227,0.288,0.303,0.389;P=0.019,0.003,0.002 and 0.000,respectively).No statistically significant correlation was found between Q-value and the diopter of refractive error (P>0.05).Both the anterior and posterior corneal Q-values varied toward the positive direction except that in the 9mm area of the posterior corneal surface at postoperative 1 month(t=-1.495,P=0.138).The increase of the anterior corneal asphericity (△Q) was more obvious than that of the posterior corneal surface and showed a positive correlation with ablation depth and a negative correlation with residual bed thickness.However,no statistically significant correlation was seen between △Q and these two parameters in the posterior corneal surface (P>0.05).Conclusion The shape of the anterior and posterior corneal surface shows more prolateness as the increase of corneal diameter in myopic eyes.Both the anterior and the posterior corneal surfaces have an oblate shift within the ablation zone 1 month after LASIK. Key words: myopia; excimer laser; asphericity; Q-value
LASIK对前、后角膜非球形的短期影响
激光原位角膜磨镶术(LASIK)常用于减少或消除近视屈光不正。有些病人在手术后抱怨视力丧失,即使他们的视力是20/20。其中一个原因是角膜非球面的改变。目的探讨LASIK术后角膜前、后锥度的短期变化。方法选取等效球屈光度为-1.30 ~ -7.50 D的近视患者54例,共107只眼,行LASIK手术。术前及术后1个月用Pentacam测定不同角膜直径(6mm、7mm、8mm、9mm)下角膜后表面的q值。研究Q值、Q变化(△Q)与术前平均球面等效屈光度(SE)、角膜中央厚度(CCT)、中心消融深度(AD)和残余层厚的相关性。临床试验前获得了所有受试者的书面知情同意。结果随着角膜直径的增大,近视眼前、后角膜表面的q值逐渐降低至负值。6mm、7mm、8mm和9mm的前、后角膜表面非球形度之间存在弱相关性(r=0.227、0.288、0.303、0.389;P分别=0.019、0.003、0.002和0.000)。q值与屈光屈光度无统计学意义(P>0.05)。术后1个月,除角膜后表面9mm区域外,前、后角膜q值均向正方向变化(t=-1.495,P=0.138)。角膜前侧非球形度(△Q)的增加较后侧明显,且与消融深度呈正相关,与残层厚度呈负相关。而角膜后表面△Q与这两项参数的相关性无统计学意义(P>0.05)。结论随着角膜直径的增大,近视眼的前、后角膜表面形态呈延长的趋势。在LASIK术后1个月,前、后角膜表面在消融区内呈扁圆形移位。关键词:近视;准分子激光;非球面性;核反应能量
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信