{"title":"Foult Indicator for polymeric insulators on 72.5 KV structures","authors":"A. A. M. de Albuquerque, R. G. D. Filho, A. L. C. Araujo","doi":"10.1109/INDUSCON.2012.6453598","DOIUrl":null,"url":null,"abstract":"The fault location in electric energy transmission structures using polymeric insulators is difficult to protect, since there are no visible signs of usage. This paper presents a real time failure detection system in polymeric insulators using an electronic system that measures the eletric current escape. The system stores leakage currents on the log file at regular time intervals and sends data to a server through a system of wireless sensor networks (WSN). A backup system is responsible for analyzing the values of each structure and generates alarms if certain current values are exceeded. The system was validated in the field on a power company distribution network.","PeriodicalId":442317,"journal":{"name":"2012 10th IEEE/IAS International Conference on Industry Applications","volume":"1 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th IEEE/IAS International Conference on Industry Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDUSCON.2012.6453598","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The fault location in electric energy transmission structures using polymeric insulators is difficult to protect, since there are no visible signs of usage. This paper presents a real time failure detection system in polymeric insulators using an electronic system that measures the eletric current escape. The system stores leakage currents on the log file at regular time intervals and sends data to a server through a system of wireless sensor networks (WSN). A backup system is responsible for analyzing the values of each structure and generates alarms if certain current values are exceeded. The system was validated in the field on a power company distribution network.
72.5 KV结构上聚合物绝缘子的故障指示器
在使用聚合物绝缘体的电力传输结构中,故障位置难以保护,因为没有明显的使用迹象。本文介绍了一种利用电子系统测量电流逸出的聚合物绝缘子故障实时检测系统。该系统定期将泄漏电流存储在日志文件中,并通过无线传感器网络(WSN)系统将数据发送到服务器。备份系统负责分析每个结构的电流值,并在超过某些电流值时产生告警。该系统在某电力公司配电网上进行了现场验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信