Crosstalk mitigation enhanced by reference conductor position

Kachout Mnaouer, B. H. T. Jamel, Choubani Fethi
{"title":"Crosstalk mitigation enhanced by reference conductor position","authors":"Kachout Mnaouer, B. H. T. Jamel, Choubani Fethi","doi":"10.1109/SPI.2010.5483549","DOIUrl":null,"url":null,"abstract":"Electromagnetic coupling to cables has been a major source of electromagnetic compatibility and electromagnetic interference problems. In this paper, we propose a simple and easy technique to reduce crosstalk between three-conductor transmission lines. We used ribbon cable with circular cylindrical section immersed in a homogeneous medium. First, we present two electric equivalent models for three-conductor transmission lines. These models allow us to calculate crosstalk between conductors. Secondly, to validate the presented models, we compare the theoretical results with simulation data. Finally, by changing the position of the reference line we demonstrate that the crosstalk changes also and the smallest value is reached when we choose the reference line in the middle of the structure.","PeriodicalId":293987,"journal":{"name":"2010 IEEE 14th Workshop on Signal Propagation on Interconnects","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE 14th Workshop on Signal Propagation on Interconnects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPI.2010.5483549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Electromagnetic coupling to cables has been a major source of electromagnetic compatibility and electromagnetic interference problems. In this paper, we propose a simple and easy technique to reduce crosstalk between three-conductor transmission lines. We used ribbon cable with circular cylindrical section immersed in a homogeneous medium. First, we present two electric equivalent models for three-conductor transmission lines. These models allow us to calculate crosstalk between conductors. Secondly, to validate the presented models, we compare the theoretical results with simulation data. Finally, by changing the position of the reference line we demonstrate that the crosstalk changes also and the smallest value is reached when we choose the reference line in the middle of the structure.
参考导体位置增强了串扰缓解
电缆的电磁耦合一直是电磁兼容和电磁干扰问题的主要来源。在本文中,我们提出了一种简单易行的技术来减少三导体传输线之间的串扰。我们采用了浸没在均匀介质中的带形电缆。首先,我们提出了三导体传输线的两个等效模型。这些模型使我们能够计算导体之间的串扰。其次,为了验证所提出的模型,我们将理论结果与仿真数据进行了比较。最后,通过改变参考线的位置,我们证明了串扰也会发生变化,当我们选择在结构中间的参考线时,串扰达到最小值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信