{"title":"Winding design of a high power medium frequency transformer","authors":"K. Iyer, W. Robbins, N. Mohan","doi":"10.1109/SPEEDAM.2014.6871956","DOIUrl":null,"url":null,"abstract":"The availability of improved magnetic materials and higher voltage rating semiconductor devices have made the design of high power medium frequency transformers feasible. The paper presents a simple design procedure to determine the core dimensions based on the area product method. A winding design procedure to use foil conductors in the high voltage side to achieve ac-to-dc resistance ratio close to 1 is also shown, providing a possible replacement to the litz wires having low window utilization factor. The paper demonstrates a design example of 13.8kV/690V, 10kHz, 50kVA transformer to validate the design methodology and the winding losses are validated using 2-D FEM.","PeriodicalId":344918,"journal":{"name":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2014.6871956","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22
Abstract
The availability of improved magnetic materials and higher voltage rating semiconductor devices have made the design of high power medium frequency transformers feasible. The paper presents a simple design procedure to determine the core dimensions based on the area product method. A winding design procedure to use foil conductors in the high voltage side to achieve ac-to-dc resistance ratio close to 1 is also shown, providing a possible replacement to the litz wires having low window utilization factor. The paper demonstrates a design example of 13.8kV/690V, 10kHz, 50kVA transformer to validate the design methodology and the winding losses are validated using 2-D FEM.