{"title":"Fault diagnosis of a GHz CMOS LNA using high-speed ADC-based BIST","authors":"J. Liobe, M. Margala","doi":"10.1109/DBT.2004.1408964","DOIUrl":null,"url":null,"abstract":"This paper presents a fault isolation method using the digital signatures from a LNA BIST solution. The fault localization capabilities of the functional test and data analysis methods are demonstrated by circuit level simulation. Also a discussion of the efficacy of this method is given. Results showed that only 16% of the resistive faults examined here cannot be mapped to its specification location in the LNA.","PeriodicalId":407554,"journal":{"name":"Proceedings. 2004 IEEE International Workshop on Current and Defect Based Testing (IEEE Cat. No.04EX1004)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 2004 IEEE International Workshop on Current and Defect Based Testing (IEEE Cat. No.04EX1004)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DBT.2004.1408964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
This paper presents a fault isolation method using the digital signatures from a LNA BIST solution. The fault localization capabilities of the functional test and data analysis methods are demonstrated by circuit level simulation. Also a discussion of the efficacy of this method is given. Results showed that only 16% of the resistive faults examined here cannot be mapped to its specification location in the LNA.