Wu Xiangjuan, Lv Wenhua, Xing Hongyan, Zou Yingquan
{"title":"Research on temperature channel calibration of data-acquisition unit of automatic weather station","authors":"Wu Xiangjuan, Lv Wenhua, Xing Hongyan, Zou Yingquan","doi":"10.1109/ICEMI.2011.6037795","DOIUrl":null,"url":null,"abstract":"A method of utilizing active resistance network to calibrate the temperature channel of data-acquisition unit is proposed in this paper. This method changes gate-source voltage by micro-controller so as to simulate the resistance. Compares resistance value measured by data-acquisition unit with the simulated resistances to calibrate the performance of the data-acquisition unit. Take DT50 data-acquisition unit in CAWS600 AWS for an example. By software commands, output current and A/D sample duration time of the data-acquisition unit temperature channel are changed to resolve the problem of parameters mismatch, then this data-acquisition unit is calibrated effectively. The experiment result shows this approach provide a reliable means to calibrate AWS data-acquisition unit.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMI.2011.6037795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A method of utilizing active resistance network to calibrate the temperature channel of data-acquisition unit is proposed in this paper. This method changes gate-source voltage by micro-controller so as to simulate the resistance. Compares resistance value measured by data-acquisition unit with the simulated resistances to calibrate the performance of the data-acquisition unit. Take DT50 data-acquisition unit in CAWS600 AWS for an example. By software commands, output current and A/D sample duration time of the data-acquisition unit temperature channel are changed to resolve the problem of parameters mismatch, then this data-acquisition unit is calibrated effectively. The experiment result shows this approach provide a reliable means to calibrate AWS data-acquisition unit.