Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Aerobic Bacteria in a Clinical Microbiology Laboratory

Myungsook Kim, M. Kwon, Hae-Sun Chung, Yangsoon Lee, D. Yong, S. Jeong, Kyungwon Lee, Y. Chong
{"title":"Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Aerobic Bacteria in a Clinical Microbiology Laboratory","authors":"Myungsook Kim, M. Kwon, Hae-Sun Chung, Yangsoon Lee, D. Yong, S. Jeong, Kyungwon Lee, Y. Chong","doi":"10.5145/KJCM.2012.15.2.60","DOIUrl":null,"url":null,"abstract":"Background: Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been used for the identification of bacteria worldwide. To our knowledge, the evaluation of MALDI-TOF MS for the identification of bacteria in Korea has not been studied. In this paper we compared the identification results of aerobic bacteria using MALDI-TOF MS to those results using conventional biochemical methods. Methods: We evaluated the performance of a MALDITOF MS system (Bruker Daltonics, Leipzig, Germany) on consecutive aerobic isolates collected from January to February of 2011 which were identified using conventional methods (biochemical testing and commercial identification kits). Either directly smearing onto the target plate or protein extraction methods were additionally used if no reliable or discordant results were obtained. Results: Among 523 isolates tested, 506 (97%) isolates had valid scores (≥2.0), 11 (2%) isolates gave intermediate scores (1.7≤ score <2.0), and 6 (1%) isolates yielded no reliable identification (score <1.7). Of the 506 valid results (score ≥2.0) by MALDI-TOF MS, the identification matched at the species level in 486 (96%) isloates, matched at the genus level in 17 (3%) isloates, and was discordant at the genus and species levels in 3 (1%) isloates. Conclusion: The overall matching rate at the species level of MALDI-TOF MS was very high. When MALDI-TOF MS did not yield reliable results by direct smear, additional direct smears or protein extraction methods could be used to obtain better results. Our results showed that MALDI-TOF MS is a very useful method for the identification of aerobic bacteria isolated in clinical microbiology laboratories. (Korean J Clin Microbiol 2012;15:60-66)","PeriodicalId":143093,"journal":{"name":"Korean Journal of Clinical Microbiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Clinical Microbiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5145/KJCM.2012.15.2.60","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Background: Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been used for the identification of bacteria worldwide. To our knowledge, the evaluation of MALDI-TOF MS for the identification of bacteria in Korea has not been studied. In this paper we compared the identification results of aerobic bacteria using MALDI-TOF MS to those results using conventional biochemical methods. Methods: We evaluated the performance of a MALDITOF MS system (Bruker Daltonics, Leipzig, Germany) on consecutive aerobic isolates collected from January to February of 2011 which were identified using conventional methods (biochemical testing and commercial identification kits). Either directly smearing onto the target plate or protein extraction methods were additionally used if no reliable or discordant results were obtained. Results: Among 523 isolates tested, 506 (97%) isolates had valid scores (≥2.0), 11 (2%) isolates gave intermediate scores (1.7≤ score <2.0), and 6 (1%) isolates yielded no reliable identification (score <1.7). Of the 506 valid results (score ≥2.0) by MALDI-TOF MS, the identification matched at the species level in 486 (96%) isloates, matched at the genus level in 17 (3%) isloates, and was discordant at the genus and species levels in 3 (1%) isloates. Conclusion: The overall matching rate at the species level of MALDI-TOF MS was very high. When MALDI-TOF MS did not yield reliable results by direct smear, additional direct smears or protein extraction methods could be used to obtain better results. Our results showed that MALDI-TOF MS is a very useful method for the identification of aerobic bacteria isolated in clinical microbiology laboratories. (Korean J Clin Microbiol 2012;15:60-66)
基质辅助激光解吸电离飞行时间质谱法鉴定临床微生物实验室需氧菌的评价
背景:基质辅助激光解吸电离飞行时间质谱法(MALDI-TOF MS)已被广泛用于细菌鉴定。据我们所知,评价MALDI-TOF MS鉴定细菌在韩国还没有研究。本文比较了MALDI-TOF质谱法和常规生化法对好氧菌的鉴定结果。方法:采用MALDITOF质谱系统(Bruker Daltonics, Leipzig, Germany)对2011年1 - 2月连续采集的好氧菌进行鉴定,并采用常规方法(生化试验和商用鉴定试剂盒)进行鉴定。如果没有得到可靠或不一致的结果,可以直接涂片到靶板上,也可以采用蛋白质提取方法。结果:523株分离菌中,506株(97%)有效分(≥2.0分),11株(2%)为中间分(1.7≤2.0分),6株(1%)鉴定不可靠(1.7分)。在评分≥2.0分的506个有效结果中,486个(96%)分离物在种水平上鉴定匹配,17个(3%)分离物在属水平上鉴定匹配,3个(1%)分离物在属和种水平上鉴定不一致。结论:MALDI-TOF质谱在种水平上的总体匹配率很高。当MALDI-TOF MS直接涂片不能得到可靠的结果时,可以采用额外的直接涂片或蛋白质提取方法获得更好的结果。结果表明,MALDI-TOF质谱对临床微生物实验室中分离的需氧细菌的鉴定是一种非常有用的方法。(中华临床微生物杂志2012;15:60-66)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信