Properties of Concrete Made with New Cement Dispersing Agent for Retempering

M. Aba, M. Shoya, K. Tokuhashi, T. Kamata, D. Mito
{"title":"Properties of Concrete Made with New Cement Dispersing Agent for Retempering","authors":"M. Aba, M. Shoya, K. Tokuhashi, T. Kamata, D. Mito","doi":"10.14359/51663209","DOIUrl":null,"url":null,"abstract":"This paper describes how it has been pointed out in recent years that many concrete structures are likely to accrue the initial defects in construction work because of the massive and complicated configuration and function of concrete structures. The service life of concrete structures and the structural performance will be lowered due to loading and environmental attack such as carbonation, frost action, and drying shrinkage. In the last few decades, various types of chemical admixtures have been developed, with emphasis on making highly durable concrete and on producing highly flowable concrete for self-compacting. A new cement dispersing agent for retempering, denoted as cement dispersing agent (CDA) was examined in this paper to confirm its effect on fundamental properties of concrete. This chemical agent is used not only to improve the performance on vibrating consolidation of fresh concrete, but also to increase the resistance to segregation of concrete. The addition of agent will promise the dispersion of cement particles and the reduction of bleeding of concrete. The CDA is a negative ion type cement dispersing agent having a main component of Polyester fiber. The benefit of CDA is given in the dosage of a small amount of agent (0.5~1.0g/m3). The improvement in vibrating consolidation of fresh concrete was depended on late addition for retempering. It was observed by the vibrating table-type consistency meter. From the tests for bleeding, setting, mechanical properties, durability, and micro structures of concrete such as Vickers hardness and pore size distribution, the benefit of CDA was also confirmed.","PeriodicalId":232163,"journal":{"name":"SP-261: 10th ACI International Conference on Recent Advances in Concrete Technology and Sustainability Issues","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-261: 10th ACI International Conference on Recent Advances in Concrete Technology and Sustainability Issues","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/51663209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes how it has been pointed out in recent years that many concrete structures are likely to accrue the initial defects in construction work because of the massive and complicated configuration and function of concrete structures. The service life of concrete structures and the structural performance will be lowered due to loading and environmental attack such as carbonation, frost action, and drying shrinkage. In the last few decades, various types of chemical admixtures have been developed, with emphasis on making highly durable concrete and on producing highly flowable concrete for self-compacting. A new cement dispersing agent for retempering, denoted as cement dispersing agent (CDA) was examined in this paper to confirm its effect on fundamental properties of concrete. This chemical agent is used not only to improve the performance on vibrating consolidation of fresh concrete, but also to increase the resistance to segregation of concrete. The addition of agent will promise the dispersion of cement particles and the reduction of bleeding of concrete. The CDA is a negative ion type cement dispersing agent having a main component of Polyester fiber. The benefit of CDA is given in the dosage of a small amount of agent (0.5~1.0g/m3). The improvement in vibrating consolidation of fresh concrete was depended on late addition for retempering. It was observed by the vibrating table-type consistency meter. From the tests for bleeding, setting, mechanical properties, durability, and micro structures of concrete such as Vickers hardness and pore size distribution, the benefit of CDA was also confirmed.
新型水泥分散剂再回火混凝土性能研究
近年来,许多混凝土结构由于其庞大而复杂的结构和功能,在施工过程中容易产生初始缺陷。混凝土结构的使用寿命和结构性能会因荷载和碳化作用、霜冻作用、干燥收缩等环境侵蚀而降低。在过去的几十年里,开发了各种类型的化学外加剂,重点是制造高度耐用的混凝土和生产高流动性的自密实混凝土。本文研究了一种新型水泥分散剂——水泥分散剂(CDA),以确定其对混凝土基本性能的影响。该化学剂不仅可以改善新拌混凝土的振动固结性能,还可以增加混凝土的抗离析性。掺加药剂有利于水泥颗粒的分散,减少混凝土的渗水。CDA是一种以聚酯纤维为主要成分的负离子型水泥分散剂。CDA的效益体现在少量药剂(0.5~1.0g/m3)的用量上。新拌混凝土振动固结性能的提高主要依赖于后期掺加再回火。用振动台式稠度仪对其进行了观测。通过对混凝土的放血、凝结、力学性能、耐久性、维氏硬度、孔隙尺寸分布等微观结构的测试,也证实了CDA的优越性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信