Design of a Flat Panel Detector for the PET-Laparoscope System Using Simulations

Xiao Yue, M. R. Liyanaarachchi, K. Shimazoe, Kenichiro Ogane, H. Takahashi, M. Takahashi, Kazuaki Hara, E. Kobayashi, I. Sakuma
{"title":"Design of a Flat Panel Detector for the PET-Laparoscope System Using Simulations","authors":"Xiao Yue, M. R. Liyanaarachchi, K. Shimazoe, Kenichiro Ogane, H. Takahashi, M. Takahashi, Kazuaki Hara, E. Kobayashi, I. Sakuma","doi":"10.1142/s2424905x2241001x","DOIUrl":null,"url":null,"abstract":"To improve spatial resolution in the PET-laparoscope system for intraoperative metastatic lymph nodes detection, design of a flat panel detector was optimized using Monte Carlo simulation tools. The performance of the new fixed detector was evaluated in point radio-source and phantom experiments. The experiment result shows that the system with the new fixed detector design has a spatial resolution better than 10[Formula: see text]mm in three dimensions, and the system can distinguish two radio-sources clearly in a 2-minute scan.","PeriodicalId":447761,"journal":{"name":"J. Medical Robotics Res.","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"J. Medical Robotics Res.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/s2424905x2241001x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To improve spatial resolution in the PET-laparoscope system for intraoperative metastatic lymph nodes detection, design of a flat panel detector was optimized using Monte Carlo simulation tools. The performance of the new fixed detector was evaluated in point radio-source and phantom experiments. The experiment result shows that the system with the new fixed detector design has a spatial resolution better than 10[Formula: see text]mm in three dimensions, and the system can distinguish two radio-sources clearly in a 2-minute scan.
基于仿真的pet -腹腔镜系统平板探测器设计
为了提高pet -腹腔镜系统术中转移淋巴结检测的空间分辨率,利用蒙特卡罗模拟工具对平板探测器的设计进行了优化。通过点辐射源实验和模体实验对新型固定探测器的性能进行了评价。实验结果表明,采用新型固定探测器设计的系统在三维空间分辨率优于10[公式:见文]mm,系统可以在2分钟的扫描时间内清晰地识别两个射源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信