Reliability-Oriented IEEE Std. 1687 Network Design and Block-Aware High-Level Synthesis for MEDA Biochips*

Zhanwei Zhong, Tung-Che Liang, K. Chakrabarty
{"title":"Reliability-Oriented IEEE Std. 1687 Network Design and Block-Aware High-Level Synthesis for MEDA Biochips*","authors":"Zhanwei Zhong, Tung-Che Liang, K. Chakrabarty","doi":"10.1109/ASP-DAC47756.2020.9045182","DOIUrl":null,"url":null,"abstract":"A digital microfluidic biochip (DMFB) enables miniaturization of immunoassays, point-of-care clinical diagnostics, DNA sequencing, and other laboratory procedures in biochemistry. A recent generation of biochips uses a microelectrode-dot-array (MEDA) architecture, which provides fine-grained control of droplets and seamlessly integrates microelectronics and microfluidics using CMOS technology. To ensure that bioassays are carried out on MEDA biochips efficiently, high-level synthesis algorithms have recently been proposed. However, as in the case of conventional DMFBs, microelectrodes are likely to fail when they are heavily utilized, and previous methods fail to consider reliability issues. In this paper, we present the design of an IEEE Std. 1687 (IJTAG) network and a block-aware high-level synthesis method that can effectively alleviate reliability problems in MEDA biochips. A comprehensive set of simulation results demonstrate the effectiveness of the proposed method.","PeriodicalId":125112,"journal":{"name":"2020 25th Asia and South Pacific Design Automation Conference (ASP-DAC)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 25th Asia and South Pacific Design Automation Conference (ASP-DAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASP-DAC47756.2020.9045182","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A digital microfluidic biochip (DMFB) enables miniaturization of immunoassays, point-of-care clinical diagnostics, DNA sequencing, and other laboratory procedures in biochemistry. A recent generation of biochips uses a microelectrode-dot-array (MEDA) architecture, which provides fine-grained control of droplets and seamlessly integrates microelectronics and microfluidics using CMOS technology. To ensure that bioassays are carried out on MEDA biochips efficiently, high-level synthesis algorithms have recently been proposed. However, as in the case of conventional DMFBs, microelectrodes are likely to fail when they are heavily utilized, and previous methods fail to consider reliability issues. In this paper, we present the design of an IEEE Std. 1687 (IJTAG) network and a block-aware high-level synthesis method that can effectively alleviate reliability problems in MEDA biochips. A comprehensive set of simulation results demonstrate the effectiveness of the proposed method.
面向可靠性的IEEE Std. 1687 MEDA生物芯片的网络设计和块感知高级合成*
数字微流控生物芯片(DMFB)实现了免疫分析、即时临床诊断、DNA测序和其他生物化学实验室程序的小型化。最近一代的生物芯片采用了微电极点阵列(MEDA)架构,它提供了对液滴的细粒度控制,并使用CMOS技术无缝集成了微电子和微流体。为了确保在MEDA生物芯片上有效地进行生物测定,最近提出了高水平的合成算法。然而,与传统dmfb的情况一样,微电极在大量使用时可能会失效,而且以前的方法没有考虑可靠性问题。在本文中,我们提出了一个IEEE标准1687 (IJTAG)网络的设计和一个块感知高级合成方法,可以有效地缓解MEDA生物芯片的可靠性问题。综合仿真结果表明了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信