{"title":"呼気試験法, ラジオアイソトープ法, アセトアミノフェン法による胃排出能検査の比較","authors":"大輔 白坂, 正明 加地, 伸郎 青山","doi":"10.1540/HEIKATSUKINZASHI1997.6.J107","DOIUrl":null,"url":null,"abstract":"The 13C-octanoic acid breath test has been thought to be one of the most important methods in gastric emptying, because it is non-invasive and needs no special device. In this study, we evaluated the gastric emptying results between the 13C-octanoic acid breath tests, scintigraphy, and acetaminophen method. Ten patients with non-ulcer dyspepsia and 4 healthy volunteers were studied. For the test meal, we used scrambled egg, white bread, and 150 ml water and into the scrambled egg, 100 mg of 13C-octanoic acid, 37 MBq 99mTc-DTPA, and 20 mg/kg body weight of acetaminophen were mixed. After eating, breath samples and scanning scintigraphic information was obtained up to 8 and 2 hours, respectively. Blood sample was obtained 45 minutes after eating and the concentration of serum acetaminophen were measured. Previously, a positive correlation between the half emptying time (t1/2) determined by breath test and scintigraphy, was reported by Ghoos et al.(1993) (y=1.12x+66.1, R2=0.79, p<0.0001) and in this study a positive correlation was found (y =0.76x +113, R2=0.29, p=0.047). There was a negative correlation between the t, 12 determined by scintigraphy and the concentration of serum acetaminophen (y=-0.12x+15.9, R2=0.40, p=0.013). In case of that 13CO2 excretion of breath test was remained, even 8 hours after eating, t1/2 and lag phase determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve in early phase was drawn like sigmoid curve, t1/2 determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve had two peak-points, there was no problem. In conclusion the 13C octanoic acid breath test is a promising and reliable method for measuring gastric emptying.","PeriodicalId":364748,"journal":{"name":"Journal of smooth muscle research. Japanese section","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of smooth muscle research. Japanese section","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1540/HEIKATSUKINZASHI1997.6.J107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The 13C-octanoic acid breath test has been thought to be one of the most important methods in gastric emptying, because it is non-invasive and needs no special device. In this study, we evaluated the gastric emptying results between the 13C-octanoic acid breath tests, scintigraphy, and acetaminophen method. Ten patients with non-ulcer dyspepsia and 4 healthy volunteers were studied. For the test meal, we used scrambled egg, white bread, and 150 ml water and into the scrambled egg, 100 mg of 13C-octanoic acid, 37 MBq 99mTc-DTPA, and 20 mg/kg body weight of acetaminophen were mixed. After eating, breath samples and scanning scintigraphic information was obtained up to 8 and 2 hours, respectively. Blood sample was obtained 45 minutes after eating and the concentration of serum acetaminophen were measured. Previously, a positive correlation between the half emptying time (t1/2) determined by breath test and scintigraphy, was reported by Ghoos et al.(1993) (y=1.12x+66.1, R2=0.79, p<0.0001) and in this study a positive correlation was found (y =0.76x +113, R2=0.29, p=0.047). There was a negative correlation between the t, 12 determined by scintigraphy and the concentration of serum acetaminophen (y=-0.12x+15.9, R2=0.40, p=0.013). In case of that 13CO2 excretion of breath test was remained, even 8 hours after eating, t1/2 and lag phase determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve in early phase was drawn like sigmoid curve, t1/2 determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve had two peak-points, there was no problem. In conclusion the 13C octanoic acid breath test is a promising and reliable method for measuring gastric emptying.