Continuous Operating Elastocaloric Heating and Cooling Device: Model-Based Parameter Study With Airflow Losses

F. Welsch, Susanne-Marie Kirsch, Nicolas Michaelis, Paul Motzki, A. Schütze, S. Seelecke
{"title":"Continuous Operating Elastocaloric Heating and Cooling Device: Model-Based Parameter Study With Airflow Losses","authors":"F. Welsch, Susanne-Marie Kirsch, Nicolas Michaelis, Paul Motzki, A. Schütze, S. Seelecke","doi":"10.1115/smasis2019-5636","DOIUrl":null,"url":null,"abstract":"\n Elastocaloric cooling uses solid-state NiTi-based shape memory alloy (SMA) as a non-volatile cooling medium and enables a novel environment-friendly cooling technology. Due to the high specific latent heats activated by mechanical loading/unloading, substantial temperature changes are generated in the material. Accompanied by a small required work input, a high coefficient of performance is achievable.\n Recently, a fully-functional and illustrative continuous operating elastocaloric air cooling system based on SMA was developed and realized. To assist the design process of an optimized device with given performance and efficiency requirements, a fully coupled thermo-mechanical system-level model of the multi-wire cooling unit was developed and implemented in MATLAB. The resulting compact simulation tool is qualified for massively parallel computation on modern multi-core computers, which allows fast and comprehensive parameter scans.\n The comparison of first measurements and simulation results showed differences in the system performance. As the airflow rate influences the thermal power and the outlet temperature significantly, the demonstrator is extended with a spatial airflow measurement system to analyze the crossflow between the hot and cold side. Following, the fluid transport model is advanced by the effect of cross-flow losses, and first modeling results with the variation of airflow rate and rotation frequency are presented.","PeriodicalId":235262,"journal":{"name":"ASME 2019 Conference on Smart Materials, Adaptive Structures and Intelligent Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASME 2019 Conference on Smart Materials, Adaptive Structures and Intelligent Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/smasis2019-5636","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Elastocaloric cooling uses solid-state NiTi-based shape memory alloy (SMA) as a non-volatile cooling medium and enables a novel environment-friendly cooling technology. Due to the high specific latent heats activated by mechanical loading/unloading, substantial temperature changes are generated in the material. Accompanied by a small required work input, a high coefficient of performance is achievable. Recently, a fully-functional and illustrative continuous operating elastocaloric air cooling system based on SMA was developed and realized. To assist the design process of an optimized device with given performance and efficiency requirements, a fully coupled thermo-mechanical system-level model of the multi-wire cooling unit was developed and implemented in MATLAB. The resulting compact simulation tool is qualified for massively parallel computation on modern multi-core computers, which allows fast and comprehensive parameter scans. The comparison of first measurements and simulation results showed differences in the system performance. As the airflow rate influences the thermal power and the outlet temperature significantly, the demonstrator is extended with a spatial airflow measurement system to analyze the crossflow between the hot and cold side. Following, the fluid transport model is advanced by the effect of cross-flow losses, and first modeling results with the variation of airflow rate and rotation frequency are presented.
连续运行弹性热冷热装置:考虑气流损失的模型参数研究
弹性热冷却采用固态镍基形状记忆合金(SMA)作为非挥发性冷却介质,实现了一种新颖的环保冷却技术。由于机械加载/卸载激活的高比潜热,材料中产生了大量的温度变化。伴随着小的需要的工作投入,一个高的性能系数是可以实现的。近年来,研制并实现了一种功能完备、具有说明性的基于SMA的连续运行弹性热风冷系统。在给定的性能和效率要求下,为了辅助优化装置的设计过程,开发了多线冷却装置的全耦合热-机械系统级模型,并在MATLAB中实现。由此产生的紧凑仿真工具可以在现代多核计算机上进行大规模并行计算,从而允许快速和全面的参数扫描。初步测量结果与仿真结果的对比显示了系统性能的差异。由于气流速率对热功率和出口温度的影响较大,因此对演示机进行了扩展,增加了空间气流测量系统来分析冷热侧的横向流动。在此基础上,提出了考虑横流损失影响的流体输运模型,并给出了随气流速率和旋转频率变化的初步建模结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信