Geoelectrical Assessment of Aquifer Potentials and its Vulnerability to Contaminant at El - Amin Proposed University Site, Minna, Niger State, Nigeria

S. J.
{"title":"Geoelectrical Assessment of Aquifer Potentials and its Vulnerability to Contaminant at El - Amin Proposed University Site, Minna, Niger State, Nigeria","authors":"S. J.","doi":"10.23880/oajwx-16000121","DOIUrl":null,"url":null,"abstract":"Vertical Electrical Sounding (VES) survey was carried out at EL - Amin proposed University site, Located along Eastern bye pass Minna, Niger State, Nigeria. It lies in the basement complex region of Northern Nigeria. The survey was carried out with the aim of determine the ground water potentials of the area and evaluate its aquifer protective capacity. The technique employed was the Vertical Electrical Sounding (VES) using Schlumberger array. A total of 48 VES points were sounded on grid profiles separated by 100 m apart with VES spacing of 100 m. Three to four layers were observed. The Stratigraphy of subsurface shows: topsoil with resistivity range from 0.4 to 277.89 Ωm, Weathered/Fracture basement layer having resistivity vary between 31.0 and 982.89 Ωm and Fresh basement with resistivity range from 19.1 to 79935.239 Ωm. The Weathered/Fractured layer was considered as aquiferous horizon. The Longitudinal Conductance and resistivity Contour maps were produced. Thirteen VES points were delineated as groundwater potential with resistivity ranging from 45.5 Ωm to 611.77 Ωm, thickness ranging between 3.5 m and 13.07 m and depth ranging from 8.8 m to 24.43 m which represent about 18.75 percent of the area. The south, south - east and north - west portions of the area are underlain by materials of moderate to good protective capacity while the western and central part of the area with thin overburden coincided with weak to poor protective capacity which will exp ose the groundwater in the area to pollution.","PeriodicalId":176565,"journal":{"name":"Open Access Journal of Waste Management & Xenobiotics","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Access Journal of Waste Management & Xenobiotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23880/oajwx-16000121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Vertical Electrical Sounding (VES) survey was carried out at EL - Amin proposed University site, Located along Eastern bye pass Minna, Niger State, Nigeria. It lies in the basement complex region of Northern Nigeria. The survey was carried out with the aim of determine the ground water potentials of the area and evaluate its aquifer protective capacity. The technique employed was the Vertical Electrical Sounding (VES) using Schlumberger array. A total of 48 VES points were sounded on grid profiles separated by 100 m apart with VES spacing of 100 m. Three to four layers were observed. The Stratigraphy of subsurface shows: topsoil with resistivity range from 0.4 to 277.89 Ωm, Weathered/Fracture basement layer having resistivity vary between 31.0 and 982.89 Ωm and Fresh basement with resistivity range from 19.1 to 79935.239 Ωm. The Weathered/Fractured layer was considered as aquiferous horizon. The Longitudinal Conductance and resistivity Contour maps were produced. Thirteen VES points were delineated as groundwater potential with resistivity ranging from 45.5 Ωm to 611.77 Ωm, thickness ranging between 3.5 m and 13.07 m and depth ranging from 8.8 m to 24.43 m which represent about 18.75 percent of the area. The south, south - east and north - west portions of the area are underlain by materials of moderate to good protective capacity while the western and central part of the area with thin overburden coincided with weak to poor protective capacity which will exp ose the groundwater in the area to pollution.
奈及利亚尼日州Minna El - Amin拟议大学场地含水层电位及其对污染物易损性的地电性评估
垂直电测深(VES)测量在EL - Amin拟议的大学场地进行,该场地位于尼日利亚尼日尔州东部bye pass Minna沿线。它位于尼日利亚北部的基底复杂地区。调查的目的是确定该地区的地下水潜力,评价其含水层保护能力。采用的技术是使用斯伦贝谢阵列的垂直电测深(VES)。在间隔100 m的栅格剖面上共测深48个测深点,测深间隔100 m。观察到三到四层。地下地层显示:表土电阻率为0.4 ~ 277.89 Ωm,风化/断裂基底电阻率为31.0 ~ 982.89 Ωm,新鲜基底电阻率为19.1 ~ 79935.239 Ωm。风化/裂缝层被认为是含水层。制作了纵向电导和电阻率等高线图。圈定了13个测点为地下水电位点,其电阻率范围为45.5 Ωm ~ 611.77 Ωm,测点厚度为3.5 m ~ 13.07 m,测点深度为8.8 m ~ 24.43 m,约占该区面积的18.75%。区内南部、东南部和西北部覆盖层为中等至较好防护层,而西部和中部覆盖层较薄,防护层较弱至较差,将使区内地下水受到污染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信