{"title":"An ICIM-CI Model Based IC EMS Evaluation Method for DSP IC in MMC-HVDC System","authors":"Yidong Tian, Wenjie Chen, Xu Yang","doi":"10.1109/EMCCompo.2019.8919904","DOIUrl":null,"url":null,"abstract":"In this paper, the failure mechanism of DSP-based control circuits in high-voltage large-current modular multilevel converter (MMC) valve towers is studied. This study combines a low-voltage integrated circuit (IC) immunity model with a new perspective on electromagnetic interference (EMI) coupling effects. A new copper layer based coupling model of MMC valve tower combined with power system and digital control IC was established. By using the new model, the EMI introduced into the IC can be quantified. This advantage translates into a new DSP electromagnetic sensitivity (EMS) evaluation method that can be used as a guide for industrial applications.","PeriodicalId":252700,"journal":{"name":"2019 12th International Workshop on the Electromagnetic Compatibility of Integrated Circuits (EMC Compo)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 12th International Workshop on the Electromagnetic Compatibility of Integrated Circuits (EMC Compo)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCCompo.2019.8919904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper, the failure mechanism of DSP-based control circuits in high-voltage large-current modular multilevel converter (MMC) valve towers is studied. This study combines a low-voltage integrated circuit (IC) immunity model with a new perspective on electromagnetic interference (EMI) coupling effects. A new copper layer based coupling model of MMC valve tower combined with power system and digital control IC was established. By using the new model, the EMI introduced into the IC can be quantified. This advantage translates into a new DSP electromagnetic sensitivity (EMS) evaluation method that can be used as a guide for industrial applications.
基于ICIM-CI模型的MMC-HVDC系统DSP集成电路EMS评价方法
本文研究了高压大电流模块化多电平变换器(MMC)阀塔中基于dsp的控制电路失效机理。本研究将低压集成电路(IC)抗扰度模型与电磁干扰耦合效应的新视角相结合。建立了基于铜层的MMC阀塔与电力系统和数字控制集成电路相结合的耦合模型。利用该模型,可以对集成电路中引入的电磁干扰进行量化。这一优势转化为一种新的DSP电磁灵敏度(EMS)评估方法,可作为工业应用的指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信