L. Guangjie, Wang Jue, Y. Ping, Zhang Shichang, Sun Yaohong
{"title":"Experimental Study on Statistical Characteristics of Surface Flashover under Nanosecond Pulse in Transformer Oil","authors":"L. Guangjie, Wang Jue, Y. Ping, Zhang Shichang, Sun Yaohong","doi":"10.1109/MODSYM.2006.365190","DOIUrl":null,"url":null,"abstract":"The insulator strength of the oil-immersed equipment is usually limited by surface flashover across the oil-solid surface. At the same time, the distributions of failure strengths have some statistical characteristics. In this paper, the flashover voltage electric strengths of several PMMA test samples are measured in transformer oil under nanosecond pulse voltage. Normal distribution is introduced to describe the statistical characteristics of the experimental data. The plot of the flashover dielectric strength on Weibull paper can also demonstrates the two-parameter Weibull distribution. The parameters of the distributions are presented and the more favorable distribution is discussed with the view of obtaining consistent results for the surface dielectric strength","PeriodicalId":410776,"journal":{"name":"Conference Record of the 2006 Twenty-Seventh International Power Modulator Symposium","volume":"154 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2006 Twenty-Seventh International Power Modulator Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MODSYM.2006.365190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
The insulator strength of the oil-immersed equipment is usually limited by surface flashover across the oil-solid surface. At the same time, the distributions of failure strengths have some statistical characteristics. In this paper, the flashover voltage electric strengths of several PMMA test samples are measured in transformer oil under nanosecond pulse voltage. Normal distribution is introduced to describe the statistical characteristics of the experimental data. The plot of the flashover dielectric strength on Weibull paper can also demonstrates the two-parameter Weibull distribution. The parameters of the distributions are presented and the more favorable distribution is discussed with the view of obtaining consistent results for the surface dielectric strength