{"title":"New State of Energy estimator for a lead-acid battery","authors":"L. Pellegrino, G. Alimonti, M. Redaelli","doi":"10.23919/AEIT.2018.8577397","DOIUrl":null,"url":null,"abstract":"The article describes a new State of Energy estimator that can be applied to an electrochemical Energy Storage System. The developed estimator was tested on a lead-acid storage system, already aged, connected to a real micro-grid. The results show an accuracy four times better than the state of the art, in particular its average error is 6%.","PeriodicalId":413577,"journal":{"name":"2018 AEIT International Annual Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 AEIT International Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AEIT.2018.8577397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The article describes a new State of Energy estimator that can be applied to an electrochemical Energy Storage System. The developed estimator was tested on a lead-acid storage system, already aged, connected to a real micro-grid. The results show an accuracy four times better than the state of the art, in particular its average error is 6%.