Fan Ye, Minghao Wang, Jiahui Xu, Mingyi Jin, Bowen Ji, Yin Chen, Yuhua Cheng, Gaofeng Wang
{"title":"A Microneedle Array-based Dry ECG Electrode With High Recording Performance for Healthcare Applications","authors":"Fan Ye, Minghao Wang, Jiahui Xu, Mingyi Jin, Bowen Ji, Yin Chen, Yuhua Cheng, Gaofeng Wang","doi":"10.1109/IFETC53656.2022.9948534","DOIUrl":null,"url":null,"abstract":"This paper reports a microneedle array (MNA) dry electrode for electrocardiogram (ECG) recordings without skin preparation. By using back side exposure and Through Polymer Via (TPV) technology, for the first time, the SU-8 microneedle arrays are fabricated on parylene C film and bonded with commercial wet electrode cap. The device has minimal invasive and can pierce through the corneum. Compared with conventional wet electrode, the contact impedance of the MNA dry electrode is lower and the signal quality of the MNA dry electrodes is higher both at rest and after motion. Since conducting gels are not required during ECG recording, the dry electrode shows potential application in long-term clinical health monitoring.","PeriodicalId":289035,"journal":{"name":"2022 IEEE International Flexible Electronics Technology Conference (IFETC)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Flexible Electronics Technology Conference (IFETC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFETC53656.2022.9948534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper reports a microneedle array (MNA) dry electrode for electrocardiogram (ECG) recordings without skin preparation. By using back side exposure and Through Polymer Via (TPV) technology, for the first time, the SU-8 microneedle arrays are fabricated on parylene C film and bonded with commercial wet electrode cap. The device has minimal invasive and can pierce through the corneum. Compared with conventional wet electrode, the contact impedance of the MNA dry electrode is lower and the signal quality of the MNA dry electrodes is higher both at rest and after motion. Since conducting gels are not required during ECG recording, the dry electrode shows potential application in long-term clinical health monitoring.
本文报道了一种无需皮肤准备的用于心电图记录的微针阵列(MNA)干电极。SU-8微针阵列首次采用背面暴露和Through Polymer Via (TPV)技术,在聚对二甲苯C薄膜上制备,并与商用湿电极帽结合。该装置具有极小的侵入性,可以穿透角质层。与传统的湿电极相比,MNA干电极的接触阻抗更低,静止和运动后的信号质量更高。由于在心电图记录过程中不需要导电凝胶,因此干电极在长期临床健康监测中具有潜在的应用前景。