{"title":"Breakdown characteristics in transformer oil under the controlled effect of thermal and electric strength","authors":"C. Lorthongkam, K. Masarat, K. Petcharaks","doi":"10.1109/CEIDP.1999.807837","DOIUrl":null,"url":null,"abstract":"Summary form only given. This paper deals with the breakdown characteristics in commercial transformer oils effected by both controlled thermal and electric strength (controlling the field efficiency factor) under DC voltage. The experiments are done under the normal practical operation condition in Thailand. The results are compared with the manufacture's specification. The commercial transformer oil from a main transformer plant is very carefully investigated in laboratory with the controlled environment similar to site condition, particularly, ambient temperature, oil moisture and purification, and temperature rise up to 100 celsius, with the test voltage up to 300 kV. The results have shown that, the such insulators has a linear characteristic in withstand with the test voltages, whereas the temperature are increased, and field factors varied.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.807837","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Summary form only given. This paper deals with the breakdown characteristics in commercial transformer oils effected by both controlled thermal and electric strength (controlling the field efficiency factor) under DC voltage. The experiments are done under the normal practical operation condition in Thailand. The results are compared with the manufacture's specification. The commercial transformer oil from a main transformer plant is very carefully investigated in laboratory with the controlled environment similar to site condition, particularly, ambient temperature, oil moisture and purification, and temperature rise up to 100 celsius, with the test voltage up to 300 kV. The results have shown that, the such insulators has a linear characteristic in withstand with the test voltages, whereas the temperature are increased, and field factors varied.
热、电强度控制下变压器油的击穿特性
只提供摘要形式。本文研究了直流电压下商用变压器油的击穿特性,并对其进行了热强度和电强度(控制场效率系数)的影响。实验是在泰国正常的实际操作条件下进行的。结果与制造商的规格进行了比较。在实验室中,对主变厂的商用变压器油进行了非常仔细的研究,控制环境与现场条件相似,特别是环境温度,油的湿度和净化,温升高达100摄氏度,测试电压高达300千伏。结果表明,随着温度的升高和电场因素的变化,该绝缘子的耐压性能呈线性变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信