DETEKSI KADAR SATURASI OKSIGEN DARAH (SpO2) DAN DETAK JANTUNG SECARA NON-INVASIF DENGAN SENSOR CHIP MAX30100

Kemalasari, M. Rochmad
{"title":"DETEKSI KADAR SATURASI OKSIGEN DARAH (SpO2) DAN DETAK JANTUNG SECARA NON-INVASIF DENGAN SENSOR CHIP MAX30100","authors":"Kemalasari, M. Rochmad","doi":"10.22146/jntt.v4i1.4804","DOIUrl":null,"url":null,"abstract":"The level of oxygen saturation in the blood (SpO2) and heart rate is one of an importent variables to determine the health of the body. The purpose of this research is to design and implement  a non-invasive tool to measure the level of  SpO2 and heart rate, so that the measurement of them becomes easier. To measure the level of SpO2 and heart rate is used the MAX30100 chip sensor, which consists of infrared led, red led and photo diode, and that are integrated with arduino uno and PC. By attach the left index fingertip on the MAX30100 chip sensor, then the sensor will transmit infrared and red lights through the fingertips and the blood molecules will absorption the lights,  while the photodioda will detect the absorption of light by the physical properties of the blood molecules, so  the level of SpO2 and heart rate per minute can be detected. Data connection between the MAX30100 chip sensor and Arduino nano is connected by I2C (Inter Integrated Circuit) which has a serial data path (SDL) and a serial clock path (SCL), and RS232 is used for connection to a PC. On the PC, the level of the SpO2, the value of heart rate and its signal will be displayed on the GUI so the results of measurement can be monitored and used to analyze body health. The test of tool was carried out on 20 people with range of age are 18 to 50 years by comparing the results of the tool that designed with an Elitech pulse oximeter tool, where the value of an average error of SpO2 is 0.84 % and heart rate is 1.6 %.","PeriodicalId":159255,"journal":{"name":"Jurnal Nasional Teknologi Terapan (JNTT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Nasional Teknologi Terapan (JNTT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/jntt.v4i1.4804","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The level of oxygen saturation in the blood (SpO2) and heart rate is one of an importent variables to determine the health of the body. The purpose of this research is to design and implement  a non-invasive tool to measure the level of  SpO2 and heart rate, so that the measurement of them becomes easier. To measure the level of SpO2 and heart rate is used the MAX30100 chip sensor, which consists of infrared led, red led and photo diode, and that are integrated with arduino uno and PC. By attach the left index fingertip on the MAX30100 chip sensor, then the sensor will transmit infrared and red lights through the fingertips and the blood molecules will absorption the lights,  while the photodioda will detect the absorption of light by the physical properties of the blood molecules, so  the level of SpO2 and heart rate per minute can be detected. Data connection between the MAX30100 chip sensor and Arduino nano is connected by I2C (Inter Integrated Circuit) which has a serial data path (SDL) and a serial clock path (SCL), and RS232 is used for connection to a PC. On the PC, the level of the SpO2, the value of heart rate and its signal will be displayed on the GUI so the results of measurement can be monitored and used to analyze body health. The test of tool was carried out on 20 people with range of age are 18 to 50 years by comparing the results of the tool that designed with an Elitech pulse oximeter tool, where the value of an average error of SpO2 is 0.84 % and heart rate is 1.6 %.
检测血氧饱和度和心动非侵入性
血氧饱和度(SpO2)和心率是决定身体健康的重要变量之一。本研究的目的是设计并实现一种无创的SpO2水平和心率测量工具,使其测量变得更加容易。使用MAX30100芯片传感器测量SpO2水平和心率,该传感器由红外led、红色led和光电二极管组成,并与arduino和PC集成。将左手食指附着在MAX30100芯片传感器上,传感器通过指尖发射红外线和红光,血液分子吸收光线,而光电二极管则通过血液分子的物理性质来检测光的吸收,从而检测到SpO2水平和每分钟心率。MAX30100芯片传感器与Arduino nano之间的数据连接通过I2C (Inter Integrated Circuit)连接,I2C具有串行数据路径(SDL)和串行时钟路径(SCL),与PC连接使用RS232。在PC机上,将在GUI上显示SpO2水平、心率值及其信号,以便监测测量结果并用于分析身体健康。将设计的工具与Elitech脉搏血氧计工具的结果进行比较,对20名年龄在18 ~ 50岁之间的人进行了测试,其中SpO2的平均误差值为0.84%,心率为1.6%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信