Fast automatic contingency analysis and ranking technique for power system security assessment

I. Musirin, Titik Khawa Abdul Rahnian
{"title":"Fast automatic contingency analysis and ranking technique for power system security assessment","authors":"I. Musirin, Titik Khawa Abdul Rahnian","doi":"10.1109/SCORED.2003.1459698","DOIUrl":null,"url":null,"abstract":"One of the essential aspects of modern power system security assessment is the consideration of any contingencies arise due to planned or unplanned line outages leading to system overloads or abnormal system voltages. Several techniques have been developed in the past few years to address this problem but computation time has been identified as the constraint making the process inefficient. This paper presents a new algorithm for automatic contingency analysis and ranking caused by line outage in a power transmission system. All steps in the algorithms including the load flow analysis; removal and reinsertion of line and overall ranking process were accommodated in one complete programme making it a complete and effective solution for contingency analysis and ranking. A pre-developed line-based voltage stability index is used as a tool in determining the severity of the contingencies. Results from experiments showed that this technique is much faster than the existing technique while reducing human error constraint.","PeriodicalId":239300,"journal":{"name":"Proceedings. Student Conference on Research and Development, 2003. SCORED 2003.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. Student Conference on Research and Development, 2003. SCORED 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2003.1459698","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

One of the essential aspects of modern power system security assessment is the consideration of any contingencies arise due to planned or unplanned line outages leading to system overloads or abnormal system voltages. Several techniques have been developed in the past few years to address this problem but computation time has been identified as the constraint making the process inefficient. This paper presents a new algorithm for automatic contingency analysis and ranking caused by line outage in a power transmission system. All steps in the algorithms including the load flow analysis; removal and reinsertion of line and overall ranking process were accommodated in one complete programme making it a complete and effective solution for contingency analysis and ranking. A pre-developed line-based voltage stability index is used as a tool in determining the severity of the contingencies. Results from experiments showed that this technique is much faster than the existing technique while reducing human error constraint.
电力系统安全评估中的快速自动应急分析与排序技术
现代电力系统安全评估的一个重要方面是考虑由于计划或计划外的线路中断导致系统过载或系统电压异常而引起的任何突发事件。在过去几年中已经开发了几种技术来解决这个问题,但计算时间已被确定为使该过程效率低下的约束。本文提出了一种新的输电系统停电事故自动分析与排序算法。算法的所有步骤包括潮流分析;线路的移除和重新插入以及整个排名过程被容纳在一个完整的程序中,使其成为应急分析和排名的完整和有效的解决方案。预先开发的基于线路的电压稳定指数被用作确定事故严重程度的工具。实验结果表明,该方法在减少人为误差约束的同时,速度比现有方法快得多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信