Two Sided Earthing Versus one Sided Earthing for Ethernet Cables

Wen Wang, Tom Hartman, C. Keyer, Jan-Kees van der Ven
{"title":"Two Sided Earthing Versus one Sided Earthing for Ethernet Cables","authors":"Wen Wang, Tom Hartman, C. Keyer, Jan-Kees van der Ven","doi":"10.1109/EMCEurope.2019.8872004","DOIUrl":null,"url":null,"abstract":"The discussion about the earthing method of Shielded Twisted Pair (STP) cables never stops. There is a difference in opinion between Local Area Network (LAN) equipment manufacturers and Electromagnetic Compatibility (EMC) specialists. LAN equipment manufacturers state that the cable screen should only be earthed on one side of the cable, because it can prevent a ground current loop. EMC specialists advise multi-point earthing, since it is the best way to increase immunity to different kinds of disturbances. To find out which earthing method gives better results, a few measurements are performed. Three kinds of test methods are used: a direct current injection (50 Hz) test, an electric fast transient bursts (EFT-B) test with a capacitive clamp and a continuous wave (CW) test using an Electromagnetic (EM) clamp.","PeriodicalId":225005,"journal":{"name":"2019 International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEurope.2019.8872004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The discussion about the earthing method of Shielded Twisted Pair (STP) cables never stops. There is a difference in opinion between Local Area Network (LAN) equipment manufacturers and Electromagnetic Compatibility (EMC) specialists. LAN equipment manufacturers state that the cable screen should only be earthed on one side of the cable, because it can prevent a ground current loop. EMC specialists advise multi-point earthing, since it is the best way to increase immunity to different kinds of disturbances. To find out which earthing method gives better results, a few measurements are performed. Three kinds of test methods are used: a direct current injection (50 Hz) test, an electric fast transient bursts (EFT-B) test with a capacitive clamp and a continuous wave (CW) test using an Electromagnetic (EM) clamp.
以太网电缆双面接地与单边接地
关于屏蔽双绞线(STP)接地方法的讨论从未停止过。局域网(LAN)设备制造商和电磁兼容性(EMC)专家之间存在意见分歧。局域网设备制造商表示,电缆屏幕应该只在电缆的一侧接地,因为它可以防止接地电流环路。电磁兼容专家建议多点接地,因为这是提高对各种干扰的免疫力的最佳方式。为了找出哪一种接地方法能得到更好的结果,进行了一些测量。使用了三种测试方法:直流注入(50 Hz)测试、电容钳的快速瞬态爆发(EFT-B)测试和电磁钳的连续波(CW)测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信