{"title":"Development and Validated RP-HPLC Method for Simultaneous Estimation of Probenecid and Cefadroxil in Pure &Combined Dosage Form","authors":"Gurumurthy. Telugu, Dr Madhuri. D","doi":"10.46624/ajphr.2019.v7.i9.003","DOIUrl":null,"url":null,"abstract":"A simple and precise, reliable, rapid, reproducible reverse phase HPLC method has been developed and validated for simultaneous estimation of Probenecid & Cefadroxil chromatography was carried out on zorbaxcC18 (4.6*150mm, 5um) column using mixture of ACN: WATER (55:45v/v) as the mobile phase at flow rate of 1.0ml for min the detection wavelength carried out at255nm the retention time of probenecid & cefadroxil was 2.061&2.462respectively. The method produce linear response in the concentration range of 10-50μg/ml of probencid&5-25μg/ml of cefadroxil the method precision for the determination of assay was below 2.0%RSD. The proposed method can be useful in quality control of bulk& pharmaceutical dosage form","PeriodicalId":233230,"journal":{"name":"American Journal of Pharmacy And Health Research","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Pharmacy And Health Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46624/ajphr.2019.v7.i9.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A simple and precise, reliable, rapid, reproducible reverse phase HPLC method has been developed and validated for simultaneous estimation of Probenecid & Cefadroxil chromatography was carried out on zorbaxcC18 (4.6*150mm, 5um) column using mixture of ACN: WATER (55:45v/v) as the mobile phase at flow rate of 1.0ml for min the detection wavelength carried out at255nm the retention time of probenecid & cefadroxil was 2.061&2.462respectively. The method produce linear response in the concentration range of 10-50μg/ml of probencid&5-25μg/ml of cefadroxil the method precision for the determination of assay was below 2.0%RSD. The proposed method can be useful in quality control of bulk& pharmaceutical dosage form