Fluctuation of anti-A and anti-B histo-blood-group antibodies in a patient after liver transplantation.

M Zimmerli, J Lerut, P Müller, A Zimmermann, U Nydegger
{"title":"Fluctuation of anti-A and anti-B histo-blood-group antibodies in a patient after liver transplantation.","authors":"M Zimmerli,&nbsp;J Lerut,&nbsp;P Müller,&nbsp;A Zimmermann,&nbsp;U Nydegger","doi":"10.1159/000222701","DOIUrl":null,"url":null,"abstract":"<p><p>The concentrations of anti-A and anti-B IgM and IgG antibodies have been studied in the serum of a patient with blood group AB who received a type A donor liver. A newly developed ABO-ELISA was used for this purpose and the values were compared to hemagglutination titers. During the postoperative study period over 8 weeks, the anti-A and anti-B levels showed a higher fluctuation than was measured in preoperative samples. Thus, in this AB-type patient, anti-A IgM varied 10-fold, anti-A IgG 20-fold and anti-B IgG 16-fold. Peak values corresponded to rejection episodes. Immunoactivation in the patient was further documented by the presence of abnormally high levels of soluble interleukin-2 receptors (sIL-2R) in serum samples. The study shows that monitoring of anti-A/B antibodies may represent a further criterion to follow-up transplanted patients during the critical postoperative graft acceptance period.</p>","PeriodicalId":77545,"journal":{"name":"Infusionstherapie (Basel, Switzerland)","volume":"18 2","pages":"91-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000222701","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infusionstherapie (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000222701","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The concentrations of anti-A and anti-B IgM and IgG antibodies have been studied in the serum of a patient with blood group AB who received a type A donor liver. A newly developed ABO-ELISA was used for this purpose and the values were compared to hemagglutination titers. During the postoperative study period over 8 weeks, the anti-A and anti-B levels showed a higher fluctuation than was measured in preoperative samples. Thus, in this AB-type patient, anti-A IgM varied 10-fold, anti-A IgG 20-fold and anti-B IgG 16-fold. Peak values corresponded to rejection episodes. Immunoactivation in the patient was further documented by the presence of abnormally high levels of soluble interleukin-2 receptors (sIL-2R) in serum samples. The study shows that monitoring of anti-A/B antibodies may represent a further criterion to follow-up transplanted patients during the critical postoperative graft acceptance period.

肝移植术后患者抗a、抗b组织血型抗体的波动。
本文研究了1例接受a型肝供体的AB型患者血清中抗a和抗b IgM和IgG抗体的浓度。新开发的ABO-ELISA用于此目的,并将其值与血凝滴度进行比较。在术后超过8周的研究期间,抗a和抗b水平的波动高于术前样本。因此,在该ab型患者中,抗a IgM变化10倍,抗a IgG变化20倍,抗b IgG变化16倍。峰值与排斥发作相对应。患者的免疫激活进一步证明了血清样本中存在异常高水平的可溶性白介素-2受体(sIL-2R)。本研究表明,在移植术后关键的接受期,抗a /B抗体的监测可能是随访移植患者的进一步标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信