{"title":"Heating of interventional instruments in magnetic particle imaging - First experiences of safety measurements","authors":"R. Duschka, H. Wojtczyk, N. Panagiotopoulos, J. Haegele, G. Bringout, J. Rahmer, C. Bontus, T. Buzug, J. Borgert, J. Barkhausen, F. Vogt","doi":"10.1109/IWMPI.2013.6528370","DOIUrl":null,"url":null,"abstract":"It seems that signal generating devices, especially those which were made of stainless steel, are not optimal for cardiovascular interventions, if these devices show ferromagnetic characteristics. CVI seem to be safe in MPI using non-signal generating devices. Labeling and visualization of devices with SPIOSs is possible and has been described in recent studies. Based on the complexity of stents themselves and different components of the stent delivery systems, it is necessary to address heating behavior of those instruments in further studies. Stents which heat up to temperatures only a few degrees above body temperature seem to be suitable for cardiovascular interventions in MPI. Further in-vivo studies are necessary to investigate heating of interventional instruments in MPI in contrast to cooling due to blood flow.","PeriodicalId":267566,"journal":{"name":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWMPI.2013.6528370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

It seems that signal generating devices, especially those which were made of stainless steel, are not optimal for cardiovascular interventions, if these devices show ferromagnetic characteristics. CVI seem to be safe in MPI using non-signal generating devices. Labeling and visualization of devices with SPIOSs is possible and has been described in recent studies. Based on the complexity of stents themselves and different components of the stent delivery systems, it is necessary to address heating behavior of those instruments in further studies. Stents which heat up to temperatures only a few degrees above body temperature seem to be suitable for cardiovascular interventions in MPI. Further in-vivo studies are necessary to investigate heating of interventional instruments in MPI in contrast to cooling due to blood flow.
磁粉成像中介入仪器的加热。安全测量的初步经验
如果信号产生装置显示铁磁特性,那么信号产生装置,特别是那些由不锈钢制成的信号产生装置,似乎不是心血管干预的最佳选择。CVI在MPI中使用非信号产生装置似乎是安全的。标记和可视化的设备与SPIOSs是可能的,并已在最近的研究中描述。基于支架本身的复杂性和支架输送系统的不同组成部分,有必要在进一步的研究中解决这些仪器的加热行为。将支架加热到仅高于体温几度的温度似乎适合于MPI患者的心血管干预。进一步的体内研究是必要的,以研究MPI中介入器械的加热与血流冷却的对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信