A Summary Report on the Mechanism of Electric Contact Failure Due to Particle Contamination

Ji Gao Zhang
{"title":"A Summary Report on the Mechanism of Electric Contact Failure Due to Particle Contamination","authors":"Ji Gao Zhang","doi":"10.1109/HOLM.2011.6034803","DOIUrl":null,"url":null,"abstract":"Particle contamination may cause serious electric contact failure. However a series of dust simulation tests could hardly reproduce the real contact problem of intermittent high resistance, i.e. very few contact failure has been found during the tests. This paper is based on testing and analyzing many practical failed connector contacts in mobile phones. The special features of the failed contacts that are due to particle contamination are then summarized. The mechanism of connector contact high resistance failure is that during micro movement, contaminated particles are accumulated and inserted at the interface instead of being pushed away. Therefore important criteria should be met: micro movement with irregular directions, variable moving lengths to wear out surface materials, stirring up particles of dust and corrosion products caused by the water soluble salts in the dust, trapping the dust particles and thus embed the particles into the contact surface, presence of some organics acting as adhesives to adhere particles together to prevent them from spreading away during micro movements. Materials within dust particles such as quartz, feldspar, mica, calcite and carbon etc. may also contribute to the contact failure. After several simulation tests it is verified that contact failure can occur only if the testing conditions and parameters include the above discussed phenomena. The testing and theoretical result have greatly convinced that further research is necessary in order to create and develop a workable simulation dust testing system for connectors.","PeriodicalId":197233,"journal":{"name":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2011.6034803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Particle contamination may cause serious electric contact failure. However a series of dust simulation tests could hardly reproduce the real contact problem of intermittent high resistance, i.e. very few contact failure has been found during the tests. This paper is based on testing and analyzing many practical failed connector contacts in mobile phones. The special features of the failed contacts that are due to particle contamination are then summarized. The mechanism of connector contact high resistance failure is that during micro movement, contaminated particles are accumulated and inserted at the interface instead of being pushed away. Therefore important criteria should be met: micro movement with irregular directions, variable moving lengths to wear out surface materials, stirring up particles of dust and corrosion products caused by the water soluble salts in the dust, trapping the dust particles and thus embed the particles into the contact surface, presence of some organics acting as adhesives to adhere particles together to prevent them from spreading away during micro movements. Materials within dust particles such as quartz, feldspar, mica, calcite and carbon etc. may also contribute to the contact failure. After several simulation tests it is verified that contact failure can occur only if the testing conditions and parameters include the above discussed phenomena. The testing and theoretical result have greatly convinced that further research is necessary in order to create and develop a workable simulation dust testing system for connectors.
微粒污染引起电触点失效机理综述
颗粒污染可能导致严重的电触点故障。然而,一系列粉尘模拟试验很难再现间歇性高电阻的真实接触问题,即在试验中很少发现接触失效。本文是在对手机中许多实际失效的连接器触点进行测试和分析的基础上进行的。然后总结了由于颗粒污染而导致的失效触点的特殊特征。连接器接触高阻失效的机理是在微运动过程中,污染颗粒在界面处积聚并插入,而不是被推开。因此,必须满足重要的标准:微运动方向不规则,移动长度可变,以磨损表面材料,搅拌灰尘颗粒和由灰尘中的水溶性盐引起的腐蚀产物,捕获灰尘颗粒并将其嵌入接触面,存在一些有机物作为粘合剂将颗粒粘在一起,以防止它们在微运动期间扩散。粉尘颗粒中的物质如石英、长石、云母、方解石和碳等也可能导致接触失效。经过多次模拟试验,验证了只有在试验条件和试验参数包含上述现象的情况下,接触才会发生失效。试验和理论结果表明,为了建立和开发一个可行的连接器模拟粉尘测试系统,有必要进行进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信