{"title":"Localization of Incipient Discharge in Power Transformer Using UHF Sensor","authors":"M. Chakravarthi, A. Giridhar, D. Sarma","doi":"10.1109/ICHVET.2019.8724280","DOIUrl":null,"url":null,"abstract":"Non-intrusive ultra high frequency detection method has been recognized as well established diagnostic tool for monitoring the condition of power transformers. This UHF method is considered as the best choice to sense the location of onsite partial discharges (PD's) in power transformer because of its good signal to noise ratio (SNR) and high sensitivity. The PD source location accuracy mainly rely on TDOA (Time differences of Arrival) of PD source and the individual four uhf sensors or sensor array placed around the transformer tank. The location of PD source is evaluated by using PSO algorithm with the set of TDOA measurements from the experiment.","PeriodicalId":165193,"journal":{"name":"2019 International Conference on High Voltage Engineering and Technology (ICHVET)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on High Voltage Engineering and Technology (ICHVET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVET.2019.8724280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Non-intrusive ultra high frequency detection method has been recognized as well established diagnostic tool for monitoring the condition of power transformers. This UHF method is considered as the best choice to sense the location of onsite partial discharges (PD's) in power transformer because of its good signal to noise ratio (SNR) and high sensitivity. The PD source location accuracy mainly rely on TDOA (Time differences of Arrival) of PD source and the individual four uhf sensors or sensor array placed around the transformer tank. The location of PD source is evaluated by using PSO algorithm with the set of TDOA measurements from the experiment.
利用超高频传感器定位电力变压器初放电
非侵入式超高频检测法已被公认为是监测电力变压器状态的成熟诊断工具。该方法具有良好的信噪比和较高的灵敏度,是电力变压器局部放电位置检测的最佳选择。局部放电源定位精度主要依赖于局部放电源的TDOA(到达时间差)和放置在变压器箱周围的单个四个超高频传感器或传感器阵列。利用实验得到的TDOA测量数据集,利用粒子群算法对PD源进行定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信