{"title":"Fuzzy approach for residual life assessment of paper insulation","authors":"Md. Manzar Nezami, S. A. Wani, S. A. Khan, N. Khera, Md Ajmal Khan","doi":"10.1109/CATCON.2017.8280178","DOIUrl":null,"url":null,"abstract":"In this paper, an effort has been made to explore the usefulness of DP (Degree of Polymerization) of cellulosic insulation paper (CIP) to monitor the condition of the transformer. The residual life of CIP of the oil-immerged power transformer is determined by detecting the content of dissolved carbon oxide and 2-FAL gases in oil. The proposed work employs Fuzzy Inference System (FIS), which offers preeminent response for calculating extent of degradation of the CIP. Using the FIS the final condition of CIP is categorized as AI (Acceptable Insulation), MD (Moderate Deterioration), ED (Extensive Deterioration) and UR (Urgent Replacement) from correlation between accumulated values of 2-FAL, CO and CO2 with DP. Furthermore, the best fuzzy membership function has been obtained for the experimental test condition. Finally the results obtained shows that the proposed method accurately monitors the condition of CIP in the oil-immerged power transformers.","PeriodicalId":250717,"journal":{"name":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON.2017.8280178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

In this paper, an effort has been made to explore the usefulness of DP (Degree of Polymerization) of cellulosic insulation paper (CIP) to monitor the condition of the transformer. The residual life of CIP of the oil-immerged power transformer is determined by detecting the content of dissolved carbon oxide and 2-FAL gases in oil. The proposed work employs Fuzzy Inference System (FIS), which offers preeminent response for calculating extent of degradation of the CIP. Using the FIS the final condition of CIP is categorized as AI (Acceptable Insulation), MD (Moderate Deterioration), ED (Extensive Deterioration) and UR (Urgent Replacement) from correlation between accumulated values of 2-FAL, CO and CO2 with DP. Furthermore, the best fuzzy membership function has been obtained for the experimental test condition. Finally the results obtained shows that the proposed method accurately monitors the condition of CIP in the oil-immerged power transformers.
纸绝缘剩余寿命评定的模糊方法
本文探讨了纤维素绝缘纸聚合度(CIP)在变压器状态监测中的作用。通过检测油中溶解性氧化碳和2-FAL气体的含量,确定了油浸式电力变压器CIP的剩余寿命。提出的工作采用模糊推理系统(FIS),为计算CIP的退化程度提供了卓越的响应。根据2-FAL、CO和CO2累积值与DP之间的相关性,使用FIS将CIP的最终状态分类为AI(可接受的绝缘)、MD(中度劣化)、ED(广泛劣化)和UR(紧急替换)。同时,得到了最适合实验测试条件的模糊隶属函数。结果表明,该方法能够准确地监测油浸式电力变压器的CIP状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信