{"title":"Evaluation of ocular refraction in silicone oil temponade eyes by the IOL-Master system","authors":"J. Shao, B. Zhu, Ying Fan","doi":"10.3969/J.ISSN.1003-0808.2010.03.022","DOIUrl":null,"url":null,"abstract":"Background The combination procedure of the removal of silicon oil and cataract extraction+intraocular lens (IOL) implantation is the main method of treating cataract in silicone oil tamponade eye.However,the conventional measuring method of the IOL power is limiting in eyes with silicone oil tamponade.The IOL-Master system is confirmed to be an ideal non-contact optical measuring instrument in vivo.Objective The aim of this study is to measure the preoperative IOL power,evaluate the accuracy of biometry with the IOL-Master system and compare the relationship between different factors and refractive error.Methods IOL power was measured in 29 silicone oil tamponade eyes of 29 patients prior to the silicone oil removal combining IOL implantation with the IOL-Master system according to different factors such as placement time,axis oculi,complications and so on.The reasons of visual acuity recovery and measurement error were discussed.Results Postoperative visual acuity was improved in all of the patients.The average predictive refractive error was 0.329±0.846 (-1.5--2D).Classified factors for the cause of disease for axis oculi included rhegmatogenous retinal detachment (RRD)(t=0.478,P=0.637),macular hole(t=0.135,P=0.895),myopia(t=0.435,P=0.667)and oil-placed time (good for less than 1 year).These factors showed an indirect relationship with errors.Conclusion Silicone oil removal combined with IOL implantation can improve visual acuity.The IOL-Master biometry is accurate,safe and convenient in measuring the IOL power in silicon oil temponade eye,but future research should be performed to decrease the measuring error. \n \nKey words: \nIOL-Master; silicone oil filled eye; intraocular lenses power measurement","PeriodicalId":186994,"journal":{"name":"Chinese Ophthalmic Research","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Ophthalmic Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3969/J.ISSN.1003-0808.2010.03.022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background The combination procedure of the removal of silicon oil and cataract extraction+intraocular lens (IOL) implantation is the main method of treating cataract in silicone oil tamponade eye.However,the conventional measuring method of the IOL power is limiting in eyes with silicone oil tamponade.The IOL-Master system is confirmed to be an ideal non-contact optical measuring instrument in vivo.Objective The aim of this study is to measure the preoperative IOL power,evaluate the accuracy of biometry with the IOL-Master system and compare the relationship between different factors and refractive error.Methods IOL power was measured in 29 silicone oil tamponade eyes of 29 patients prior to the silicone oil removal combining IOL implantation with the IOL-Master system according to different factors such as placement time,axis oculi,complications and so on.The reasons of visual acuity recovery and measurement error were discussed.Results Postoperative visual acuity was improved in all of the patients.The average predictive refractive error was 0.329±0.846 (-1.5--2D).Classified factors for the cause of disease for axis oculi included rhegmatogenous retinal detachment (RRD)(t=0.478,P=0.637),macular hole(t=0.135,P=0.895),myopia(t=0.435,P=0.667)and oil-placed time (good for less than 1 year).These factors showed an indirect relationship with errors.Conclusion Silicone oil removal combined with IOL implantation can improve visual acuity.The IOL-Master biometry is accurate,safe and convenient in measuring the IOL power in silicon oil temponade eye,but future research should be performed to decrease the measuring error. Key words: IOL-Master; silicone oil filled eye; intraocular lenses power measurement
IOL-Master系统评价硅油模压眼屈光性
背景硅油摘除联合白内障摘出+人工晶状体植入术是治疗硅油填塞眼白内障的主要方法。然而,传统的人工晶状体度数测量方法在硅油填塞眼中存在一定的局限性。IOL-Master系统是一种理想的体内非接触式光学测量仪器。目的测定术前人工晶状体度数,评价IOL- master系统生物计量的准确性,比较不同因素与屈光不正的关系。方法根据放置时间、眼轴、并发症等不同因素,对29例硅油填塞患者的29只眼进行人工晶状体植入术前的人工晶状体度数测定。讨论了造成视力恢复和测量误差的原因。结果所有患者术后视力均有明显改善。平均预测屈光误差为0.329±0.846(-1.5—2D)。引起眼轴病变的因素包括孔源性视网膜脱离(RRD)(t=0.478,P=0.637)、黄斑裂孔(t=0.135,P=0.895)、近视(t=0.435,P=0.667)和涂油时间(≤1年)。这些因素与误差有间接关系。结论硅油去除联合人工晶状体植入术可提高视力。IOL- master生物测量技术测量硅油模压眼的人工晶状体度数准确、安全、方便,但其测量误差有待进一步研究。关键词:IOL-Master;硅油填充眼;人工晶体度数测量
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信